![Sony MG40 Series Скачать руководство пользователя страница 126](http://html.mh-extra.com/html/sony/mg40-series/mg40-series_command-reference-manual_411003126.webp)
4-38
(E)
MG40 Series
Subnet mask
Th
is function is used to set and acquire the subnet mask.
Th
e value which has been set is refl ected the next time the system is started up.
When the subnet mask is acquired aft er its setting has been changed, the subnet mask set before the change
is refl ected will be acquired.
Set
Setup
mode
Ethernet
The command sets the subnet mask.
Command format
NSM=<Subnet mask>
<Subnet mask>
0.0.0.0 to 255.255.255.255 (Factory setting: 255.255.255.0)
Return format
Execution results
Target
MG41 main unit
Save setting values
Setting values saved. (Th
e setting values are saved at the same time as the setting
command is executed.)
Examples of use
Transmission :
NSM=255.255.0.0
Return
:
OK000
Compatible command
None
Acquire
Setup
mode
Ethernet
Measurement
mode
The command acquires the subnet mask.
Command format
NSM?
Return format
NIP=<Subnet mask>
<Subnet mask>
0.0.0.0 to 255.255.255.255
Target
MG41 main unit
Examples of use
Transmission :
NSM?
Return
:
NIP=255.255.255.0
Compatible command
None
Содержание MG40 Series
Страница 2: ...MG40 Series ...
Страница 4: ...ii J MG40 Series ...
Страница 8: ...1 4 J MG40 Series ...
Страница 20: ...3 4 J MG40 Series ...
Страница 68: ...5 6 J MG40 Series ...
Страница 72: ...ii E MG40 Series ...
Страница 76: ...1 4 E MG40 Series ...
Страница 88: ...3 4 E MG40 Series ...
Страница 136: ...5 6 E MG40 Series ...