4-24
(E)
MG40 Series
Data header
Th
is function is used to set and acquire the data header.
Set data header
Setup
mode
Ethernet
The command sets the data header.
Command format
HDR=<Header>
<Header>
00 : None
01 : Type 1 (Factory setting)
02 : Type 2
For details on the types, refer to
Return format
Execution results
Target
MG41 main unit
Save setting values
Setting values saved.
Examples of use
Transmission :
HDR=01
Return
:
OK000
Compatible command
None
Acquire data header
Setup
mode
Ethernet
Measurement
mode
The command acquires the data header setting.
Command format
HDR?
Return format
HDR=<Header>
<Header>
00 : None
01 : Type 1
02 : Type 2
Target
MG41 main unit
Examples of use
Transmission :
HDR
?
Return
:
HDR=01
Compatible command
None
Data header On
(Compatible command only)
Setup
mode
Ethernet
The command sets the data header to type 1.
Command format
None
Return format
Execution results
Target
MG41 main unit
Examples of use
Transmission :
HON
Return
:
OK000
Compatible command
HON
Data header Off
(Compatible command only)
Setup
mode
Ethernet
The command sets the data header to “None.”
Command format
None
Return format
Execution results
Target
MG41 main unit
Examples of use
Transmission :
HOF
Return
:
OK000
Compatible command
HOF
Содержание MG40 Series
Страница 2: ...MG40 Series ...
Страница 4: ...ii J MG40 Series ...
Страница 8: ...1 4 J MG40 Series ...
Страница 20: ...3 4 J MG40 Series ...
Страница 68: ...5 6 J MG40 Series ...
Страница 72: ...ii E MG40 Series ...
Страница 76: ...1 4 E MG40 Series ...
Страница 88: ...3 4 E MG40 Series ...
Страница 136: ...5 6 E MG40 Series ...