5-48 (E)
Digital Cinema Dual System
3. Add the line below.
Add the bold-faced portion in the same way as step 2 according to the type of the audio processor to
be connected.
.
When connecting DCP300/CP650/CP750 using the RS232C cable
com.sony.dcinema.serial.impl.
CP750Control
.connection=Serial
.
When connecting DCP1000/CP750/CP850/CSP850A/FCQA8631 using the LAN cable
com.sony.dcinema.serial.impl.
CP750Control
.connection=Ethernet
When connecting the audio processor using the LAN cable, it is required to register the IP address
of the audio processor.
4. Save the changed contents and end the registration. (Refer to steps 6 to 8 in Section 5-13-1.)
5-13-4. Setting of GPIO
Perform the GPIO setting for operating the automation of a theater or accepting the signals from other
systems.
There are GPI and GPO in GPIO (General-Purpose Input/Output). GPI is used to accept a signal from an
external theater automation system. GPO is used to output a signal to a theater automation system.
It is necessary to set according to the information on which signal the theater automation system can send
and receive, and how the theater automation system and server are connected.
Creation of profile
1. Tap the “Configuration” tab.
2. Tap
[System]
→
[GPIO|Profile]
.
Profile
pane
Screen example
[System]
[GPIO|Profile]
GPIO Channel pane
Automation
pane