5-41 (E)
Digital Cinema Dual System
5-11. Network
Setting
The network of this system is set and the IP address of external equipment is registered, as described
below. Multiple system connection destinations (IP addresses) can be registered when operating this
system using a computer. The connection destination can be easily switched by tapping the number in the
left corner of a Status-Auditorium screen.
1. Tap the “Configuration” tab.
2. Tap
[System]
→
[Network]
.
The Network screen is displayed.
Network setting of the system
.
SMS Server Settings/IP Address: Enter the IP address of the CTRL port on the rear panel of a server.
.
SMS Server Settings/DNS Address: Register a DNS server.
.
Extended Settings/Data Port:
Enter the IP address of the DATA port on the rear panel of a server.
Tap
[Apply]
after you have entered each IP address. The system is automatically restarted.
n
.
192.168.6.x cannot be set to the IP address.
.
Set so that CTRL and DATA ports do not belong to the same sub-net.
.
Enter 0.0.0.0 to the IP address of an unused port.
IP address registration of external equipment
.
Extended Settings/eCNA:
Enter the IP address of the theater automation equipment when
connecting with theater automation equipment that conforms to an
eCNA protocol.
.
Extended Settings/Audio Processor: Enter the IP address of the audio processor when connecting with
an audio processor through LAN.
Tap
[Apply]
after you have entered each IP address.
Screen example
[System]
[Network]
Other Auditorium pane
SMS Server Settings pane
[Apply]
Extended
Settings pane