background image

DIGITAL CINEMA DUAL SYSTEM

DIGITAL CINEMA PROJECTOR PACKAGE

SRX-R515P

DIGITAL CINEMA PROJECTOR

SRX-R515

HDD UPGRADE KIT

LKRA-009

DUAL SYSTEM ACCESSORY KIT

LKRA-010

3D FILTER AND HOLDER

LKRA-011

PROJECTOR AUTO CALIBRATION BOX

LKRA-PCAB1

2D PROJECTION LENS

LKRL-Z511

LKRL-Z514

LKRL-Z519

PROJECTION LAMP

LKRM-U330

LKRM-U331

LKRM-U450

INSTALLATION MANUAL
1st Edition

Содержание LKRA-009

Страница 1: ...NEMA PROJECTOR SRX R515 HDD UPGRADE KIT LKRA 009 DUAL SYSTEM ACCESSORY KIT LKRA 010 3D FILTER AND HOLDER LKRA 011 PROJECTOR AUTO CALIBRATION BOX LKRA PCAB1 2D PROJECTION LENS LKRL Z511 LKRL Z514 LKRL Z519 PROJECTION LAMP LKRM U330 LKRM U331 LKRM U450 INSTALLATION MANUAL 1st Edition ...

Страница 2: ...Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le mode d emp...

Страница 3: ...用遮断装置を設けるか 機器使用中に 容易に抜 き差しできるコンセントに電源プラグを接続してくだ さい WARNING This unit has no power switch When installing the unit incorporate a readily accessible disconnect device in the fixed wiring or connect the power cord to a socket outlet which must be provided near the unit and easily accessible so that the user can turn off the power in case a fault should occur WARNUNG Dieses Gerät hat keinen Netzschalt...

Страница 4: ......

Страница 5: ...2 Language Setting 5 12 E 5 4 3 Owner Information Setting 5 13 E 5 4 4 Date Time Setting 5 14 E 5 4 5 High Altitude Mode Setting Cooling Setting 5 15 E 5 5 Performing the Marriage 5 16 E 5 6 Projector Startup 5 17 E 5 7 Screen Positioning Procedure 5 18 E Manual Structure Purpose of this manual 3 E Related manuals 3 E Trademarks 3 E 1 Installation Outline 1 1 System Configuration Example 1 1 E 1 2...

Страница 6: ...ction 5 36 E 5 8 9 Calling the Registered Image Information FUNCTION MEMORY Function 5 37 E 5 9 Color Space Conversion CSC Adjustment 5 38 E 5 10 Check of Video Signal and Audio Output 5 40 E 5 11 Network Setting 5 41 E 5 12 Folder Setting 5 43 E 5 13 Setting of External Equipment 5 45 E 5 13 1 Change in ini File 5 45 E 5 13 2 Registration of UPS 5 47 E 5 13 3 Registration of Audio Processor 5 47 ...

Страница 7: ...tem that is required for the block level service For the information about the models and parts common with the Digital Cinema Projector Package SRX R515P R510P see the Service Manual of SRX R515P R510P Maintenance Manual See the Maintenance Manual of the Digital Cinema Projector Package SRX R515P R510P It describes the information about the system maintenance periodic check cleaning etc Trademark...

Страница 8: ......

Страница 9: ...calibration box hereafter referred to as Calibration camera Conduit Sub projector Theater network LAN Device with external video HDMI Video signal audio data USB HDD Touch panel monitor Audio processor USB 2 0 HUB VGA USB 2 0 RS 232C D sub 9 pin CTRL2 RS 232C D sub 9 pin CTRL1 GPIO USB 2 0 3 0 RS 232C D sub 9 pin LAN Automation system HDMI distributor Lighting controller Curtain controller ...

Страница 10: ...ht eye is output from the other projector Be sure to use the lens of the same model for the two projectors Attach the 3D filter for the left eye to the main projector and the 3D filter for the right eye to the sub projector The image distortion correction data is saved in the function memory Therefore perform the image distortion correction adjustments as many as the number of the registered funct...

Страница 11: ...ilter and holder the following tools are also required Long screwdriver Phillips head Socket wrench subtense 13 mm Calibration camera LKRA PCAB1 Corrects the misalignment of convergence between the two projectors An alignment DCP is also required Refer to Section 6 Update package Prepare all of the following software modules to configure the dual system Unified Update Manager UUM Module to make th...

Страница 12: ...nner Subtense 8 mm supplied with the lens Subtense 24 mm for flexible leveler Subtense 30 mm for nut M20 USB mouse USB keyboard For the connection setting with the external equipment such as audio processor and UPS LTC cable Required only when configuring the 4D system Refer to Section 7 LTC converter Prepare the LTC converter and Ethernet cable as required Ethernet cable ...

Страница 13: ...Front view Left side view Refer to the optional lens list Air Intake Air Intake Air Intake Heat exhaust Input output terminal LKRL LIST No LKRL L REMARKS 1 Z511 258 297 2 Z514 230 283 3 Z519 244 1 4 External Dimensions 1 4 1 Projector ...

Страница 14: ...ema Dual System Top view Right side view Rear view Bottom view Unit mm Heat exhaust Heat exhaust Air Intake Air Intake Air Intake Air Intake Air Intake Air Intake Air Intake AC power cable 10 M8 for fixing the projector ...

Страница 15: ...1 7 E Digital Cinema Dual System 1 4 2 Server Front view Top view Right side view Rear view Unit mm Input output terminal AC power cable Heat exhaust Air Intake ...

Страница 16: ...KRA 011 3 1 Installation of Server 3 2 Connection with Projector 3 3 Power Connection 3 5 Installation of CRU DATAPORT Carrier 5 1 Update to Dual System Software 5 2 System Startup and Login 5 4 Initial Setting 5 5 Performing the Marriage 5 6 Projector Startup 5 7 Image Adjustment Flow 2 8 4 Check Adjustment of 3D Filter Position 5 8 Image Adjustment 5 9 Color Space Conversion CSC Adjustment 5 10 ...

Страница 17: ...ght left at the same time Parts information Handle arm 4 164 849 02 4 pcs Pipe short 4 164 850 02 2 pcs Pipe long 4 164 851 02 2 pcs M8 bolt 2 590 262 02 or 11 4 pcs In the case of attaching the pipe long to the right and left side of projector 1 Loosen the nut in the direction of the arrow A then insert the handle arm in the direction of the arrow B 2 Tighten the nut to fix the handle arm 3 Attac...

Страница 18: ...nema Dual System 4 Insert the pipe long into the handle arms then fix the pipe with the two M8 bolts 5 Attach the pipe long on the other side in the same way Pipe long Pipe long Handle arm Handle arm Pipe long M8 bolts ...

Страница 19: ...back and forth of projector t The procedure is the same as the pipe long 1 Loosen the nut in the direction of the arrow A then insert the handle arm in the direction of the arrow B 2 Tighten the nut to fix the handle arm 3 Attach the handle arm to the adjuster of other three portions by repeating steps 1 and 2 ...

Страница 20: ...igital Cinema Dual System 4 Insert the pipe short into the handle arms then fix the pipe with the two M8 bolts 5 Attach the pipe short on the other side in the same way Pipe short Pipe short Pipe short M8 bolts ...

Страница 21: ...equential order However do not connect the power cord in Section 2 5 before Sections 2 1 to 2 4 are completed 2 1 Installation of Duct Attach the 8 inch duct to the duct connecting portion on the rear side of the projector top portion n When attaching the duct be careful not to bend the duct for exhausting the air smoothly For the required exhaust air volume refer to 1 3 Required Equipment Tools ...

Страница 22: ...installation removal of lens be careful not to touch the lens board 1 Raise the lens fixing lever toward the side with the lock button pushed all the way in lock released n If you raise the lens fixing lever without pushing the lock button the lock button and lens fixing lever will be damaged Be sure to push the lock button and check that the lock is released before raising the lever Lens fixing l...

Страница 23: ...lever Lens Lens fixing lever Lens 2 Attach the lens to the projector while firmly holding the lens not to drop it and aligning the position n When attaching the lens to the projector insert it straight 3 Lower the lens fixing lever to fix the lens ...

Страница 24: ...nstall the six lamps on SRX R515P R515 Do not mix two different lamp types i e 330 W and 450 W in a projector If you do so an error will occur and the projector will not start up B1 lamp B2 lamp B3 lamp Left side of projector Right side of projector A1 lamp A2 lamp A3 lamp Front side of projector Front side of projector ...

Страница 25: ...osen the screw with drop safe lower the two hooks and then remove the intake grille A in the direction of the arrow A 2 Lower the lamp door latch to open the lamp door Intake grille A A Screw with drop safe Hooks Lamp door Lamp door latch ...

Страница 26: ... lamp door n When holding the lamp be careful not to touch the connector contact portion Push near the PUSH mark of the lamp to insert it securely 4 Attach the remaining lamps by repeating steps 2 and 3 5 To install the intake grille A reverse the removal procedure 2 4 Installation of Touch Panel Monitor 1 Attach the TPC mounting plate with the four screws ...

Страница 27: ...ion of the touch panel monitor can be changed by rotating the TPC arm block assembly 1 Remove the three screws 2 Rotate the TPC arm block assembly in the direction of the arrow 3 Fix the TPC arm block assembly with the three screws Cable clamper PSW4 x 10 TPC arm block assembly Cable clamper PSW4 x 10 PSW4 x 10 TPC arm block assembly ...

Страница 28: ...2 8 E Digital Cinema Dual System Touch panel monitor Screw Screw Screw 4 Attach the touch panel monitor with the three screws ...

Страница 29: ...rver Touch panel monitor Cable clamper Cable Knob Cable clamper 5 Pull the knob and tilt the touch panel monitor in the direction of the arrow t When you pull the knob the touch panel monitor can be moved and when you release the knob the touch panel monitor is fixed 6 Connect each cable to the connector on the bottom of the touch panel monitor 7 Fix the cable with the two cable clampers 8 Pull th...

Страница 30: ...ocedure w Connection of the main power and the electric wiring work should be done by qualified electricians only Do not plug the power cord into the power supply before completing all of the following connecting operations 1 Remove the four screws then remove the terminal block cover 2 Remove the screw then remove the cable clamp 3 Remove the screw then remove the ground terminal Screws Terminal ...

Страница 31: ...o the end of the ground wire 5 Attach the ground terminal removed in step 3 to the ground wire then fix it with the screw 6 Route the power cord through the hole on the bottom of the terminal block then fix each terminal with the screw as shown in the illustration 7 Fix the power cord using the cable clamp and screw 8 Attach the terminal block cover ...

Страница 32: ... details refer to 5 8 Image Adjustment 1 Loosen the nut 2 Adjust the projector tilt by rotating the adjuster Rotate clockwise direction 2 To raise the height of projector Rotate counterclockwise direction 3 To lower the height of projector 3 Fix the adjuster by tightening the nut toward the adjuster pipe Nut Adjuster Adjuster pipe Example of tilted projector ...

Страница 33: ...kit consists of the following parts DIF 243 board dual system board 2 pcs Tamper harness for the main projector 1 pc Tamper harness 1 for the sub projector 1 pc Tamper harness 2 for the sub projector 1 pc Shield plate assembly 1 1 pc Shield plate assembly 2 1 pc Conduit cable box 1 set Conduit support 2 pcs 1 Touch the projector chassis to discharge the static electricity 2 Turn off the breaker of...

Страница 34: ...the panel U6B in the direction of the arrow 7 Remove the six screws then remove the shield plate 8 Remove the two screws then remove the blank panel t Keep the removed shield plate and blank panel Blank panel PSW 4 x 10 PSW 4 x 10 Shield plate PSW 4 x 10 PSW4 x 10 Panel U6B ...

Страница 35: ...e illustration n Insert the DIF 243 board into the board guide rails securely If the board goes off the board guide rails it may damage the board parts resulting in a failure 0F E D C B A 9 8 7 6 5 4 3 2 1 0F E D C B A 9 8 7 6 5 4 3 2 1 0F E D C B A 9 8 7 6 5 4 3 2 1 0F E D C B A 9 8 7 6 5 4 3 21 Rotary switches DIF 243 board Main projector Rotary switches Sub projector S700 S900 S700 S900 Rotary ...

Страница 36: ...unit Connect them securely without making mistakes Tamper harness DIF 243 board U shaped groove Route the harness through the gap Keep the harness length of approx 10 cm from the U shaped groove Connector A Tamper harness Connector A three terminals Connector B Connector C Ground wire 500 mm 50 mm Cloth label DS01 Tamper harness 1 Connector A Connector B 550 mm Cloth label DS03 Cloth label DS02 Ta...

Страница 37: ...ctor CN003 on the SU 165 board then connect it to the connector B of the tamper harness 1 2 Connect the tamper harness 2 to the connector CN003 on the SU 165 board PSW 4 x 10 PSW 4 x 10 To the connector three terminals of the tamper harness of conduit To the sub projector side Tamper harness CN003 SU 165 board Main projector Harness CN003 SU 165 board Harness Connector B Connector A three terminal...

Страница 38: ... harness is routed through the gap of the panel 15 Attach the shield plate assembly 1 to the main projector with the six screws removed in step 7 of the main projector 16 Attach the shield plate assembly 2 to the sub projector with the six screws removed in step 7 of the sub projector Tamper harness Tamper harness DIF 243 board PSW 4 x 10 Gap PSW 4 x 10 Shield plate assembly 1 for main projector P...

Страница 39: ...igital Cinema Dual System 17 Connect the conduit assembly in the following procedure t Route the conduit cable on the lens side of the main projector and sub projector Conduit cable Main projector Sub projector ...

Страница 40: ...he tamer harnesses Panel U6B Display port cables Conduit box Tamper harnesses Panel U6B Display port cables LINK A IN LINK A OUT LINK B IN LINK B OUT Conduit box Tamper harnesses Main projector Sub projector Display port cable A IN Display port cable B IN Display port cable A OUT Display port cable B OUT LINK A IN LINK A OUT LINK B IN LINK B OUT ...

Страница 41: ...al Cinema Dual System 3 Hang the four hooks of the conduit box on the grooves of the shield plate 4 Secure the conduit box with the two screws K2 6 x 5 K2 6 x 5 Panel U6B Four hooks Grooves Conduit box Conduit box ...

Страница 42: ...is unit by performing steps 3 to 6 in the reverse order 19 Attach the conduit support with the two hexagon socket bolts 20 Secure the conduit cable with the cable tie Hexagon socket bolts 8 x 12 Conduit support Conduit support Conduit cable Cable tie ...

Страница 43: ...e installation environment attach the 3D filter and holder with the lock pin located on the underside 2 8 1 Component Parts The 3D filter and holder consist of the following parts Hexagonal spacer 8 pcs Spring washer 8 pcs Washer 8 pcs PSW cross recessed hexagon head bolt 8 pcs 3D filter 2 pcs 3D filter bracket assembly 2 pcs PSW4 x 8 8 pcs Required tools Long screwdriver Phillips head Socket wren...

Страница 44: ...ou want to open close the 3D filter in the right direction refer to How to open close the 3D filter in the right direction described later 1 Put the spring washer and washer on the hexagonal spacer then attach it to the lens shift block Hexagonal spacer Spring washer Lens shift block Washer ...

Страница 45: ...with the screwdriver may damage the cross recessed head Attach the 3D filter bracket assembly with the lock pin located on the upper side When attaching the screws be extremely careful to prevent the 3D filter bracket assembly from dropping 4 Repeat step 3 to temporarily secure the remaining three screws 5 Fully tighten the four screws to secure the 3D filter bracket assembly PSW cross recessed he...

Страница 46: ...irection of the 3D filter holder 1 Remove the four screws then remove the 3D filter holder 2 Turn the 3D filter holder 180 degrees 3 Attach the 3D filter holder with the four screws 4 Attach the 3D filter bracket assembly Refer to step 1 in Section 2 8 2 Lock pin 3D filter holder PSW 4 x 10 PSW 4 x 10 Lock pin 3D filter holder PSW 4 x 10 PSW 4 x 10 ...

Страница 47: ...3D filter that is opened closed in the left direction 1 Pull the lock pin in the direction of the arrow A then pull the support frame 3 in the direction of the arrow B 2 While pushing the two clips of the slide rails in the direction of the arrow A pull out the support frame 3 in the direction of the arrow B Support frame 3 Lock pin A B Lock pin Support frame 3 Clip Clip A A B ...

Страница 48: ...R or 3D filter assembly L 3D filter assembly R or 3D filter assembly L Upper side R Support frame 3 3D filter assembly R or 3D filter assembly L Upper side L Set the 3D filter assembly with the label side placed in the back Attach it in the direction that the letter can be read correctly in either case of opening closing in the right left direction Set the 3D filter assembly with the label side pl...

Страница 49: ...rails of the bracket 6 Slide the upper and lower rails on the bracket side until they click 7 Close the filter block 8 Check if the filter block slides correctly Lock pin Rail Rail Rail Slide the upper and lower rails until they click Filter block Clip Clip Filter block ...

Страница 50: ...tem 2 8 4 Adjustment Adjust the main projector connected to the server first then adjust the sub projector Procedure 1 Loosen the four screws so that the 3D filter bracket moves back and forth PSW 4 x 10 3D filter bracket PSW 4 x 10 ...

Страница 51: ...oject the test pattern Frame Adjust Refer to steps 1 to 3 in Section 5 8 1 4 Adjust the 3D filter bracket by moving it back and forth so that the distance between the projected test pattern and filter frame meets the specification Test pattern Filter frame B A Specification A B 50 mm 3D filter bracket ...

Страница 52: ...2 32 E Digital Cinema Dual System 5 Fully tighten the four screws PSW 4 x 10 PSW 4 x 10 ...

Страница 53: ...he 3D filter bracket and support frame 1 as shown in the illus tration Otherwise there is a risk of pinching fingers between them 2 Perform the adjustment by turning the 3D filter bracket in the direction of the arrow so that the shadow moves out of screen 3 Tighten the screws loosened in step 1 7 Perform the adjustment of the other projector in the same way PSW 4 x 10 PSW 4 x 10 3D filter bracket...

Страница 54: ......

Страница 55: ...ibed here Perform the instal lation of the device in the rack correctly according to the caution and procedure described below w To prevent the rack from falling or moving fix the rack on a flat and steady floor and the like using bolts or others If the rack falls due to the weight of the equipment it may cause death or serious injury Be sure to use the specified rack mount kit If not injury may r...

Страница 56: ...according to step 1 in 3 1 2 Placing the Server on the Pedes tal 2 Loosen the two screws with drop safe then remove the front panel assembly 3 Mount the server on the rack with the four rack mounting screws Screw with drop safe Front panel assembly Screw with drop safe Rack Server Rack mounting screws Rack mounting screws ...

Страница 57: ...rque 0 80 0 12 N m 3 1 2 Placing the Server on the Pedestal 1 Turn the server upside down then attach the four feet with the four screws 2 Place the server on the pedestal n Check that the pedestal is not unstable Screw with drop safe Front panel assembly Screw with drop safe B4 x 8 B4 x 8 B4 x 8 B4 x 8 Foot Foot Foot Foot ...

Страница 58: ...3 4 E Digital Cinema Dual System 3 2 Connection with Projector Rear of server PCI express cable accessory Ethernet cable Ethernet cable Main projector Sub projector HUB ...

Страница 59: ...e power is not supplied correctly with UPS not used the contents data can be broken Rear of server Rear of UPS AC adaptor cable accessory USB cable accessory Bottom of touch panel monitor USB cable Power cord VGA cable accessory Power cord available on request AC adaptor ...

Страница 60: ...3 core mains lead Appliance Connector Plug conforming to the proper ratings Voltage Ampere Never use an injured power cord 3 5 Installation of CRU DATAPORT Carrier The CRU DATAPORT carrier is attached to CRU DATAPORT of the server Please purchase and install the CRU DATAPORT carrier as required 1 Remove the front panel from the server Refer to step 2 in Section 3 1 1 2 Remove the screw then remove...

Страница 61: ...tem 4 Remove the three screws then remove the CRU cover 5 Remove the two screws then remove the cover from the rear of the CRU DATAPORT carrier PSW3 x 6 PSW3 x 6 CRU unit assembly CRU cover PSW3 x 6 Cover Rear CRU DATAPORT carrier ...

Страница 62: ...tem 6 Connect the CRU DATAPORT carrier to the connector CN12 on the IF 1180 board 7 Fix the CRU DATAPORT carrier with the three screws CRU unit assembly CRU DATAPORT carrier IF 1180 board CN12 CRU DATAPORT carrier PSW3 x 6 PSW3 x 6 ...

Страница 63: ... screw 9 Insert the CRU unit assembly into the server then fix it with the two screws n When inserting the CRU unit assembly be careful not to pinch the harness 10 Attach the front panel Refer to step 4 in Section 3 1 1 CRU unit assembly PSW3 x 6 PSW3 x 6 Harness ...

Страница 64: ......

Страница 65: ...l System 4 1 Projector 4 1 1 Connection Diagram Section 4 Connection with External Equipment Main projector Audio cables AES External reproduction device External reproduction device HDMI cables Audio processor Audio processor ...

Страница 66: ...H11 12 _ 23 CH13 14 G 11 CH13 14 24 CH13 14 _ 12 CH15 16 G 25 CH15 16 13 CH15 16 _ Connect the shielding wire of a cable to the shell so as to suppress radiation In the 4D system when ini file setting is changed LTC is output For details refer to Section 7 AUDIO OUTPUT UNBAL D sub 25 pin External view Pin No Signal name Pin No Signal name 1 CH1 2 14 NC 2 CH3 4 15 NC 3 NC 16 NC 4 NC 17 NC 5 NC 18 N...

Страница 67: ... connecting the cable to the GPIO connector and VGA connector Use the inch screw thread for the D sub connector of the cable to be connected to GPIO Rear of server Front of server Audio processor USB HDD RS 232C cable Theater network LAN Theater network LAN Ethernet cables Theater equipment control system Theater equipment control system USB cable D sub 25 pin female D sub 25 pin female GPIO cable...

Страница 68: ...l view Pin No Signal name Pin No Signal name 1 IN1 14 IN1 GND 2 IN1 _ 15 IN0 3 IN0 GND 16 IN0 _ 4 OUT4 N C 17 OUT4 COM 5 OUT4 N O 18 OUT3 N C 6 OUT3 COM 19 OUT3 N O 7 OUT2 N C 20 OUT2 COM 8 OUT2 N O 21 OUT1 N C 9 OUT1 COM 22 OUT1 N O 10 OUT0 N C 23 OUT0 COM 11 OUT0 N O 24 24 V 12 24 V 25 24 V 13 GND Connect the shielding wire of a cable to the shell so as to suppress radiation GPIO 2 D sub 25 pin ...

Страница 69: ...pply 24V 24V DC Three terminals of GPIO1 and three terminals of GPIO2 are common Total rated current of 6 terminals is 0 5 A GPO equivalent circuit and specification Items Maximum value OUT N C COM N O terminal working voltage DC 30 V Current DC between OUT N O and OUT COM terminals 1 A Current DC between OUT N C and OUT COM terminals 1 A GPI equivalent circuit and specification Items Maximum Stan...

Страница 70: ...4 6 E Digital Cinema Dual System AUDIO CTRL D sub 9 pin External view Pin No Signal name 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Connect to Audio Processor manufactured by Dolby ...

Страница 71: ...compatible with the dual system The update to the dual system compatible version is performed only once after configuring the system Required update package Unified Update Manager UUM Module to make the system to be recognized as the dual system Module to update the software to the latest version For obtaining the update package contact your local Sony Sales Office Service Center ...

Страница 72: ...r may have occurred in the standby power supply Identify the problem portion by referring to Section 2 11 in the Service Manual of the Digital Cinema Projector Package SRX R515P R510P 2 Push the SYSTEM SW switch on the front of the server to turn on the power The POWER indicator lights up in green When the server is started the Login screen is displayed on the monitor 3 Login to the system with th...

Страница 73: ...firm that playback has been stopped 2 Confirm that the projector is in standby mode 3 Confirm that ingest operations have been stopped n Before updating set the projector to the standby mode The update of projector cannot be performed in the state other than the standby mode lamp ON or OFF mode Do not play back or ingest content or perform any other operations during an update When updating via a ...

Страница 74: ... to update the software to the latest version Turn the power of the projector off and on When the server is started the projector restarts and enters the standby mode while Initializing is dis played in the status message display window located on the back side of the main projector and sub projector When the projector enters the standby mode turn off and on the power switch on the back side of th...

Страница 75: ...r light up in red n If the MAIN indicator does not light up in red even though the power switch is set to ON an error may have occurred in the standby power supply Identify the problem block by referring to Section 2 11 in the Service Manual of the Digital Cinema Projector Package SRX R515P R510P 2 Push the SYSTEM SW switch on the front of the server to turn on the power The POWER indicator lights...

Страница 76: ...ser Name abbreviated user name Name formal user name Password admin Administrator s0nyadm1n user1 Projectionist 1111 showmgr Show Manager 2222 trsetup Theater Installer setup Addition of User 1 Start up GUI Refer to Section 5 3 for how to use the GUI screen 2 Tap the Configuration tab 3 Tap User Role The User Role screen is displayed User list Login Screen example User Role Users pane New in the U...

Страница 77: ...wManager Administrator and Maintenance The items that can be operated in each Role are as follows Enable Item that can be operated in the Role Disable Item that cannot be operated in the Role Role Operation item Content Management SPL Management Show Control Audit Log Report User Management Projectionist Disable Disable Enable Disable Disable ShowManager Enable Enable Enable Enable Disable Adminis...

Страница 78: ...want to enable operation t There are items that can be selected for each Role Definition 4 Tap OK 5 3 About the GUI Screen The adjustment of the system is performed by using GUI The outline such as the configuration of GUI screen is described here Main configuration of GUI screen Status tab Auditorium Status Error History Schedule tab SPL tab Library tab Configuration tab Status Library System Pro...

Страница 79: ... fire alarm has occurred or when a serious problem has occurred in the projector Library Used for the setting related to the folder System Used for the marriage of projector and server TPC screen adjustment etc The impor tant settings and adjustments regarding the system are mainly performed by using this menu Projector 2D Used for the adjustment of the 2D lens User Role Used for the addition or c...

Страница 80: ... TPC Calibration Setting The touch panel monitor is adjusted 1 Start up GUI Refer to Section 5 2 2 2 Tap the Configuration tab 3 Tap System Server Info The Server Info screen is displayed 4 Tap TPC Calibration The TPC Calibration dialog is displayed Screen example System Server Info TPC Calibration Calibration Screen example ...

Страница 81: ... 6 A mark is displayed on the screen Tap the mark Perform this three times The place where the mark is displayed is changed When the last mark is tapped the adjustment is completed and then the display is returned to the Server Info screen Tap the mark ...

Страница 82: ...anguage Setting dialog is displayed 5 Select the language in Language English Chinese 6 Set the display type of date in Date and time in Time as required t The display type of Date and Time varies depending on the language selected in step 5 7 Tap Apply t The setting is reflected at the point of restart of this system after Apply is tapped Screen example System Server Info Language Setting Apply S...

Страница 83: ... tab 3 Tap System Server Info The Server Info screen is displayed 4 Tap Owner Information The Owner Information dialog is displayed 5 Set Owner Organization Region Location and Screen as required There is no problem to set only arbitrary items 6 Tap Apply Server Info Screen example Owner Information System Apply Screen example ...

Страница 84: ...iguration tab 3 Tap System Server Info The Server Info screen is displayed 4 Tap Date Time The Date Time Setting dialog is displayed 5 Set Time Zone There is no problem to set only arbitrary items 6 Set Date and Time in Secure Clock Setting as required Screen example Date Time System Server Info Screen example ...

Страница 85: ... server NTP Secure Time NTP Server can be entered The IP address of NTP Server can be entered 8 Tap Apply 9 When Time Zone is changed restart the system manually 5 4 5 High Altitude Mode Setting Cooling Setting When using this system in high altitude areas it is required to set the mode according to the altitude If the setting is not performed correctly the lamp performance is degraded which may r...

Страница 86: ...Marriage column is Fail Contact your local Sony Sales Office Service Center Door Closed column is Fail Check the installation of the cabinet of projector Projector Authentication column is Fail After the projector and server shutdown perform OFF ON of the breaker of the projector and tap Marriage If the state does not change after 10 minutes have passed contact your local Sony Sales Office Service...

Страница 87: ...n green and the LAMP indicator blinks in green When the projector is started the LAMP indicator stops blinking and stays lit Then MAIN indicator and LAMP indicator are lit in green t If the projector does not start check if an error message is displayed on the GUI screen If the mes sage is displayed take measures according to the message 3 Tap Close to close the Projector Lamp Control screen Power...

Страница 88: ... memo ry When performing the periodic correction of the dual system that is already adjusted 5 Perform the adjustment using the calibration camera Steps 1 to 4 are not required Adjustment procedure 1 Run the two projectors for 30 minutes or more 1 Tap Power ON of the main projector from GUI 2 Tap Power ON of the sub projector from GUI 3 Run both two projectors for 30 minutes or more In the meantim...

Страница 89: ...horizontal keystone Also when the image is tilted in the horizontal direction correct the tilt of the image by adjusting the height of the projector feet In this stage the horizontal projection angle of the main projector is almost perpendicular to the screen when viewed from above The center of image is not yet aligned with the center of screen which is not a problem Fix the main projector positi...

Страница 90: ...djust the lens focus of the main projector 6 Set the test pattern of the main projector to OFF 7 Register the setting in the function memory for Flat in the main projector 4 Registration of function for Scope image 1 Call the setting for Scope registered in 2 2 8 from the function memory 2 Project the Frame Adjust Scope test pattern from the main projector 3 Adjust the V shift of Electric Shift of...

Страница 91: ...ther This is performed for correcting the tilt of sub projector with respect to the main projector in the horizontal direction 4 Mechanical adjustment of vertical and horizontal center line 1 Adjust the H shift of the lens shift block feet height and zoom of the sub projector so that the vertical center line of the test pattern of the sub projector is overlapped with the vertical center line of th...

Страница 92: ...tion memory Perform the further adjustment of the image of the two projectors using the electric image distortion correction function Basically perform the correction of the sub projector using the main projector as a reference Perform the correction of the main projector only when the adjustment is not enough only by the cor rection of the sub projector Specify the CALIBRATION mode of the calibra...

Страница 93: ...ction memory that can be deleted and tap Clear In any case register store the setting data in the function memory after the adjustment For the registration procedure refer to Section 5 8 8 n Register the function in both main projector and sub projector Use the same function number and name in the main projector and sub projector 5 8 1 Zoom Focus Adjustment 1 Tap the Configuration tab 2 Tap Projec...

Страница 94: ...n the three V shift lock screws and three H shift lock screws 3 Adjust the image position in the vertical direction by rotating the V shift knob 4 Adjust the image position in the horizontal direction by rotating the H shift knob 5 Tighten the three V shift lock screws and three H shift lock screws H shift knob V shift knob Lens shift block H shift lock screws 3 pcs V shift lock screws 3 pcs ...

Страница 95: ... using the touch panel Refer to Section 5 8 3 Since the adjust able tolerance in the vertical and horizontal directions varies depending on the field angle of contents it needs to be corrected in the following procedure When you want to perform the V shift adjust the image position with flat vertically longest field angle then correct the image center position with other field angles scope HD When...

Страница 96: ... the V shift or H shift is moved over the maximum adjustment range the image degradation or vignetting lack of image in the outer edge portion may occur or the image center position may not be adjusted when zooming There is no problem to use them over the maximum adjust ment range if you understand these conditions However it is recommended to use them within the maxi mum adjustment range for ordi...

Страница 97: ...ing and so on in the case of using the V shift and H shift with the lens shift block 1 Tap the Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed 3 Tap Electric Shift The Electric Shift screen is displayed 4 Adjust the V shift or H shift using the slide bar or the _ Screen example Projector 2D Set Function Electric Shift Screen example ...

Страница 98: ...form the mask processing because a keystone occurs when the projector is tilted Mask processing 1 Tap the Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed 3 Tap Masking Adjust The Adjust Masking screen is displayed 4 Adjust the masking amount Tap the adjustment point and adjust H Adjust and V Adjust using the slide bar or _ Setting value is increased _ Setting...

Страница 99: ...nema Dual System 5 8 5 Overlaying the Images of Two Projectors 1 Tap the Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed Screen example Projector 2D Set Function Distortion Adjust ...

Страница 100: ... values of the adjustment points are reset to 0 For details on the adjustment procedure refer to Distortion adjustment procedure described later n If possible adjust the image only by changing the value of sub projector without changing the value of the main projector 5 Tap Close to close the Adjust Distortion screen Distortion adjustment procedure Here about which point of the image projected on ...

Страница 101: ...ust the projectors so that the width of the main projector image is the same as that of the sub projector image Adjust the projectors so that the arrow B length length of the line connecting the two circles in the illustration of the main projector is the same as that of the sub projector Adjust V of Linearity and Size for the horizontal lines in the same way 3 Adjust the tilted and bowed image Wh...

Страница 102: ...of H and V of Left Mid Area so that the center of left half of the sub projector image is aligned with that of the main projector image Adjust the value of H and V of Right Mid Area so that the center of right half of the sub projector image is aligned with that of the main projector image 6 Adjust both ends of the center line of the right half and left half of the image Adjust the corresponding a...

Страница 103: ... Projector Color Adjustment Tool version 2 0 1 8 or later is used for the uniformity adjustment For the adjustment procedure refer to the Technical Manual of the Projector Color Adjustment Tool For obtaining the tool and the Technical Manual contact your local Sony Sales Office Service Center The Lighting Pattern for 2D lens and the uniformity corresponding to it are registered How to determine th...

Страница 104: ...6 S M Side masking TB M Top bottom masking Screen width mm Brightness lumen Screen example Lighting Pattern pane Six lamps A1 lamp B1 lamp A2 lamp B2 lamp A3 lamp B3 lamp Five lamps A1 lamp B1 lamp A2 lamp B2 lamp A3 lamp B3 lamp Four lamps A1 lamp B1 lamp A2 lamp B2 lamp A3 lamp B3 lamp Three lamps A1 lamp B1 lamp A2 lamp B2 lamp A3 lamp B3 lamp Two lamps A1 lamp B1 lamp A2 lamp B2 lamp A3 lamp B...

Страница 105: ...e registered in the function memory is set Lamp Power The lamp power value level and fine adjustment value that has been set is registered in the function memory Luminance The luminance at that time is registered in the function memory not the lamp power setting value level and fine adjustment value that has been set When the registered function memory is called the lamp power value level and fine...

Страница 106: ...e registration and calling of function memory cannot be performed Register the function in both main projector and sub projector Use the same function number and name in the main projector and sub projector 1 After the adjustment and setting are completed tap the Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed 3 Select the function memory that you want to reg...

Страница 107: ...tion 1 Tap the Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed 3 Select the registered data that you want to call from the Function List pane 4 Tap Load The confirmation message is displayed 5 Tap OK Screen example Load Set Function Function List pane Projector 2D ...

Страница 108: ...multiple adjustment images are displayed is measured by using the color meter and then the color space conver sion is performed based on the measurement results n Perform the CSC adjustment in the state of luminance level that has been set slightly higher than the level that you want to set For example if you want to set the luminance level to 14ft L with the 2D screen set it to approx 16ft L Adju...

Страница 109: ...values 6 Project the test pattern in the Test Pattern pane Gray8 7 Measure the x and y values 8 Type the measurement results in the Input Color Measurement pane 9 Tap Calculate 10 Check that all differences between respective values and values in the Target Color Gamut pane are less than 0 002 11 If there is any item having the difference of 0 002 or more perform steps 4 to 10 again ...

Страница 110: ... then tap Load B 4 Tap the reproduction button to reproduce the data t To display the test contents perform the setting in the following procedure 1 Install the color meter 2 Tap the Configuration tab Tap Projector 2D Set Function The Set Function screen is displayed 3 Set the input channel in the Input Channel pane Refer to Section 5 14 11 Screen example Auditorium Load B Load Content screen Load...

Страница 111: ...a DNS server Extended Settings Data Port Enter the IP address of the DATA port on the rear panel of a server Tap Apply after you have entered each IP address The system is automatically restarted n 192 168 6 x cannot be set to the IP address Set so that CTRL and DATA ports do not belong to the same sub net Enter 0 0 0 0 to the IP address of an unused port IP address registration of external equipm...

Страница 112: ...efer to Section 5 13 3 An audio processor applicable to network control is only CP750 Enter 0 0 0 0 to the IP address of an unused port To register the IP addresses of other projection systems when controlling multiple pro jection systems using a computer 1 Tap New in the Other Auditorium pane The New Auditorium screen is displayed 2 Select the Auditorium number and enter the IP address of the pro...

Страница 113: ... value of each item varies depending on the type of external folder to be created 4 Tap New The created external folder is added to the list of the Source List pane t To change setting select a folder in the Source List pane and tap Edit after you have changed the set ting To delete an external folder select a folder in the Source List pane and tap Delete Screen example Library Folders Configurati...

Страница 114: ... xx yyy xx xx xx xx yyy xx xx xx xx IP address yyy Folder name Server Address No entry is required Server Port No entry is required Source Access Information pane Domain Enter a domain name when using a domain Username Password Enter the user name and password for gaining access to an external folder t To register the network sharing folder in the system the destination external folder needs to be...

Страница 115: ...system is 1 20 or later and LMT 300 is selected for Storage Type type the IP address of the destination LMT 300 Ctrl port in Server Address Server Port 21 Source Access Information pane Domain No entry is required Username Password No entry is required 5 13 Setting of External Equipment 5 13 1 Change in ini File In some settings the ini file text file in which initialization is described and whose...

Страница 116: ...local Sony Sales Office Service Center 4 Execute the command below and open SMSMgrServer_custom ini vi home sms apps conf SMSMgrServer_custom ini 5 When changing an ini file move the cursor to the line to be changed then press the i key on the USB keyboard The current state then enters the edit mode 6 Press the Esc key on the USB keyboard enter wq and press the Enter key The contents of change are...

Страница 117: ...in Section 5 13 1 5 13 3 Registration of Audio Processor When this server and an audio processor are connected using RS 232C or a LAN cable the volume can be controlled and muted from this unit to the audio processor To use this function it is necessary to set the type of the audio processor to be connected and the connection method The ini file text file in which initialization is described and w...

Страница 118: ...the changed contents and end the registration Refer to steps 6 to 8 in Section 5 13 1 5 13 4 Setting of GPIO Perform the GPIO setting for operating the automation of a theater or accepting the signals from other systems There are GPI and GPO in GPIO General Purpose Input Output GPI is used to accept a signal from an external theater automation system GPO is used to output a signal to a theater aut...

Страница 119: ...en a signal is high Low Active when a signal is low 5 Tap Apply A profile is set t To change the registered profile refer to Change in profile To delete the registered profile refer to Deletion of profile Change in profile 1 Place a mark in the check box for the profile to be changed in the Profile pane and tap Edit n Initialization items DEFAULT_INPUT_PULSE DEFAULT_OUTPUT_PULSE and DEFAULT_OUTPUT...

Страница 120: ...ialog Associating a GPIO channel only an output pin with an Automation command The signal output to a theater facility control system can be executed as the Automation command by associating a GPIO channel only output pin with an Automation command The Automation command can be manually accessed from a Status tab Auditorium screen or inserted into SPL as a cue 1 Tap New in the Automation pane The ...

Страница 121: ...ssociated with other operations undefined is displayed in the Name column of other GPIO channel using the profile being associated with the above GPIO channel When undefined is tapped the settable profiles are displayed in pull down list You can change the association by selecting the desired profile from the pull down list Associating a GPIO channel only an input pin with the playback start trigg...

Страница 122: ...ows Connect the USB memory to the server and perform the operation using GUI of the touch panel Perform the operation using the browser from PC When using PC the license file can be installed either from the USB memory or after being copied to PC Here the procedure of installation by connecting the USB memory to the server and performing the operation using GUI of the touch panel is described 1 Co...

Страница 123: ... installing the license file Perform the procedure in Section 4 2 in the Maintenance Manual of the Digital Cinema Projector Package SRX R515P R510P and select ATMOS License Activate package when setting the Unified Update Man ager UUM package Check of license activation Check if the license activation has been performed correctly 1 Tap Status tab Status 2 Check the license activation status by the...

Страница 124: ...les Office Service Center The license that became unnecessary can be deactivated To deactivate it an update file for the deactivation is required Perform the procedure in Section 4 2 in the Maintenance Manual of the Digital Cinema Projector Package SRX R515P R510P and select ATMOS License Deactivate package when setting the Unified Update Manager UUM package ...

Страница 125: ...es An Emergencies screen is displayed 3 In the Emergency Signal pane select the trigger during processing execution Select Fire Alarm for processing during generation of a fire alarm Select Projector Stop for processing during occurrence of an error in a projector 4 Select the processing performed when the trigger is received Multiple items can be selected Stop Current Show Stops the current show ...

Страница 126: ...t is set in Emergency Recovery is output A maximum of four signals can be output from a GPIO channel only an output pin when the trigger set is canceled They are used to cancel the control item set in step 3 The items in the Automation pane of GPIO Profile are displayed as the options of the output signal t Fire Alarm and Projector Stop are canceled in the following cases For Fire Alarm When a Fir...

Страница 127: ... the lower field When tapping the ends with check box Delete a file ending with the character string input to the lower field Older than Delete a file that was more previously created than the speci fied number of days Total Size Delete a file larger than the specified size MB Recursively find files in this folder Files in a folder are also treated for deletion 5 In the Deletion Interval pane set ...

Страница 128: ...Tap the Configuration tab 2 Tap System Shortcut Assignment The Shortcut Assignment screen is displayed 3 Select No blank in which no shortcut is registered in the Shortcut List and then tap New The New Shortcut Setting screen is displayed Screen example System Configuration tab Shortcut Assignment Shortcut List pane Shortcut Delete Edit New Apply Screen example Apply ...

Страница 129: ...t item to be deleted in the Shortcut List pane then tap Delete Prepare Open Douser and Close Douser that have been registered at the factory cannot be changed and deleted 5 Tap Apply in the Shortcut Assignment screen The setting is saved 5 14 4 Log Output Setting This system can output a log once a day in the specified time Log files are output as an individual file in units of one day 1 Tap the C...

Страница 130: ...nal folder 5 Set the time to be output in the Correct Logs daily at pane t All checked logs are sequentially output in the specified time It takes much time to perform internal processing when outputting an SMS log Therefore set in a time zone in which no current show or ingestion is performed 6 The item to be output can be selected when outputting an Audit log 1 Tap Filter An Audit Log Filter Set...

Страница 131: ...ngs Export Folder of the Export pane and select the external folder to be exported To export the setting on a GUI screen tap Export in Export GUI Settings pane t The folder for exporting general settings must be registered in advance Refer to Section 5 12 Connect a PC to the server when exporting the setting on a GUI screen The exported setting data are saved in the folder set as the Firefox downl...

Страница 132: ...ts of 10 ms between _250 ms and 250 ms with respect to a video output The audio output delay cannot be set during playback When the setting value is 0 ms the audio of this system is output approx 20 ms advanced with respect to the video output CC Closed Caption output delay setting Closed Caption Delay A CC output can be adjusted in units of 10 ms between _3000 ms and 3000 ms with respect to a vid...

Страница 133: ...k the specified external folder periodically and read it automatically when new KDM is contained 1 Tap the Configuration tab 2 Tap Library Folders The Folder screen is displayed 3 Tap Browse in the KDM Hot Folder pane and select the external folder t A maximum of two external folders can be specified in a KDM hot folder An external folder must be registered in advance Refer to Section 5 12 Screen ...

Страница 134: ...ficate from the PC is as follows 1 Connect the PC to this system set Firefox and then perform login Refer to Section 5 15 2 Click the Configuration tab 3 Click System Certificate Info The Certificate Information screen is displayed 4 Select the certificate you want to retrieve in the pull down menu of the Download pane and click Download 5 Select the saving destination and click OK Screen example ...

Страница 135: ...adjustment is required for some reason perform it in the following procedure 1 Tap the Configuration tab 2 Tap Projector 2D Adjust Registration The Adjust Registration screen is displayed 3 Tap On in the Adjust Registration pane 4 Adjust the screen position horizontal and vertical of each image R G and B using _ respec tively Screen example Adjust Registration pane Projector 2D Adjust Registration...

Страница 136: ... the Lighting Pattern is set to 5 or less SRX R515P R515 when you tap ON of this screen from the standby or lamp off state all lamps six lamps for SRX R515P R515 will be lit When you start up the projector using Power ON the lamps corresponding to the number of lamps stored in the memo ry will be lit 1 Tap the Configuration tab 2 Tap Projector 2D Adjust Lamp The Adjust Lamp screen is displayed 3 T...

Страница 137: ...e signal from the optional board is input to the projector or you select the signal from the HDMI IN terminal 1 Tap Configuration tab 2 Tap Projector 2D Set Function The Set Function screen is displayed Screen example Projector 2D Set Function Configuration tab Input Channel pane AUX Info pane ...

Страница 138: ...the pull down menu of the Input Channel pane IMB Input A Not used in this system HDMI_1 Input B Signal from HDMI IN1 HDMI_2 Input C Signal from HDMI IN2 DS Input D Signal from the server The input channel setting value can be registered in the function memory Refer to Section 5 8 8 Screen example Input Channel pane The channel of the HDMI input of the main unit is also switched here Main projector...

Страница 139: ... multiple TABs of the Web browser Before switching the terminal to be operated perform logout 5 15 1 Connection and Startup of PC 1 Install Firefox in PC For the version to be installed refer to n described above 2 Connect PC and a server XCT S10 through a network t Use a CTRL port of the server XCT S10 3 Change the setting of Firefox Refer to Changing the setting of Firefox 4 Enter https xxx xxx ...

Страница 140: ...described as I Understand the Risks The lower part of the label is opened and a new message is displayed 2 Click the Add Exception button A dialog box for connection confirmation is displayed 3 Click the Confirm Security Exception button A GUI login screen is displayed Screen example Confirm Security Exception button ...

Страница 141: ...e Enter about config Screen example I ll be careful I promise button 5 15 2 Changing the Setting of Firefox 1 Enter about config in the address bar and press the Enter key A configuration screen for gaining access to the setting screen is displayed ...

Страница 142: ...le Search field 2 Click the I ll be careful I promise button A Firefox setting screen is displayed 3 Double click browser sessionstore resume_from_crash in the setting value list t You can refine the search by entering part of the name you want to search in the search column ...

Страница 143: ... changes to false in the Value and that the whole line changes to a bold face 5 Double click browser cache disk enable in the setting value list 6 Check that the true changes to false in the Value and that the whole line changes to a bold face 7 Double click browser cache memory enable in the setting value list ...

Страница 144: ... cache offline enable in the setting value list 10 Check that true changes to false in the Value and that the whole line changes to a bold face 11 Double click dom max_script_run_time in the setting value list The Enter integer value dialog box is opened 12 Type 30 in the box and then click the OK button The dialog box is closed 13 Check that 30 is displayed in Value and that the whole line change...

Страница 145: ...projection system will shut down The MAIN indicator and LAMP indicator of the projector change to blink in green which indicates that the system is in cooling state When the cooling is completed the LAMP indicator changes to light in red Wait as it is 3 When the MAIN indicator and LAMP indicator change to light in red and the IMB indicator changes to blink in red turn off the power by setting the ...

Страница 146: ......

Страница 147: ...era 6 1 1 Precautions for Installation Install the calibration camera in a stable location free from vibration Make sure that there are no obstructions between the calibration camera and screen Make sure the calibration camera s lens is clean When installing the calibration camera in a projection room adhere to the following Keep the projection room as dark as possible Install the calibration came...

Страница 148: ...alibration camera on a tripod for example 2 Connect the supplied connection cables as shown in the illustration Sub projector Calibration camera Main projector CTRL1 CTRL2 to RS 232C connector on main projector to RS 232C connector on sub projector Connection cable Connection cable ...

Страница 149: ...ystem 3 Connect the supplied AC adaptor to the calibration camera The calibration camera turns on and the following main menu is displayed in the LCD panel AC adaptor P C A B U T I L I T Y S E L E C T E N T E R A L I G N M E N T ...

Страница 150: ...4 Function name When an application is being executed 1 Application name 2 Status 3 Notification 4 Warning message area 5 Function name P C A B U T I L I T Y S E L E C T E N T E R A L I G N M E N T F A N N O R O T A T I O N 1 2 3 4 A L I G N M E N T A D J 1 2 4 3 5 Q U I T S T A R T D O N E S T A R T C A L I B R A T I O N ...

Страница 151: ...tally compressed Application names and functions will display when you operate the touch sensor However the display will return to camera pass through mode after a short time When an error occurs 1 Application name 2 Application error 3 Warning message area 4 Function name t For details on error code refer to the Service Manual of Digital Cinema Dual System A L I G N M E N T C A L Q U I T A L I G ...

Страница 152: ...adjustment using the calibration camera s application must be performed with the same align ment CPL being played back from both projectors Select CPLs for which the mask configurations for the target screen and projector function settings match and manually adjust the screen with the CPL in a paused state t For obtaining the alignment DCP contact your local Sony Sales Office Service Center 4 Chec...

Страница 153: ...ub projector s projected image using the main projector s image as a reference overlaying both images on each other The main projector will only be adjusted if calibration on the sub projector alone is insufficient As adjustments are performed continuously based on previous calibration values calibration times will be shorter with smaller shifts in the projected images AVERAGE Corrects distortions...

Страница 154: ...The test pattern used for the adjustment of camera position and zoom is smaller when compared with the 1 2 to 4 0 setting value Therefore the camera position and zoom can be adjusted easily 3 Check the test pattern and check whether manual adjustment of the projectors was performed prop erly If manual adjustment was not performed properly tap F1 QUIT and repeat the procedure from 6 2 1 Preparation...

Страница 155: ...he zoom process is properly completed the following screen appears 5 Verify that the four areas in the test pattern displayed on the calibration camera are not significantly askew If they are significantly askew make fine adjustments to the calibration camera s position to achieve proper horizontal and vertical alignment If you want to move the calibration camera or otherwise retry the adjustment ...

Страница 156: ...vergence Adjust test pattern appears check the calibration results Check the color of the markers on the calibration points of the captured calibration image Green Calibration successful Amber Calibration errors exceed the specific margin of error Be sure to verify the image visually Red Divergence exceeds the scope of electronic calibration Adjust the projectors manually and then try performing c...

Страница 157: ... 6 2 3 Disconnecting the Calibration Camera 1 Check that the main menu is displayed on the LCD panel 2 Disconnect the AC adaptor from the calibration camera 3 Disconnect the connection cables from both projectors A L I G N M E N T 㧪 C O N F I R M R E T U R N Q U I T S A V E S A V E A L I G N M E N T D A T A T O P J T F U N C T I O N S A L I G N M E N T 㧪 S A V E D Q U I T A L I G N M E N T D A T A...

Страница 158: ......

Страница 159: ...me 4D system needs both LTC output and network automation cue some needs only LTC output and some needs neither of them For details contact your local Sony Sales Office Service Center t Control type A Control type B Control type C LTC output Needed Needed Not needed Network automation cue Needed Not needed Not needed 7 2 LTC Output LTC is output from No 7 pin of AUDIO OUTPUT BAL port refer to Sect...

Страница 160: ...r Example of connection between dual system and 4D system When using LTC output AUDIO OUTPUT BAL port and 4D system LTC port should be connected by LTC cable If 4D system does not accept LTC input directly use an adequate LTC converter For the details contact your local Sony Sales Office Service Center When performing 4D system control command transmission by network automation cue Connect the ser...

Страница 161: ...fferent network segment from that of the CTRL port Usually the theater network is configured so that the 4D port and CTRL port or DATA port if it is used of server are in the same subnet 7 4 2 Server Settings Edit SMSMgrServer_custom ini to activate LTC output from IMB Setting for SMSMgrServer_custom ini Add the following line to SMSMgrServer_custom ini LTC_MODE 0001 After editing SMSMgrServer_cus...

Страница 162: ...ntrol 1 Login to GUI with admin or showmgr or trsetup installer account 2 Tap the Configuration tab 3 Tap System Network The Network screen is displayed 4 Tap New The New Automation screen is displayed New System Network Automation Name pane Port pane Protocol pane IP Address pane ...

Страница 163: ...mNo100001 automatically Consecutive multiple blanks will be replaced with a single blank upon registered 6 Type or select the setting in the IP Address pane Port pane and Protocol pane TCP UDP to communicate with the 4D system n Do not input the IP address that cannot communicate with the 4D system in the IP Address pane Otherwise it may cause a problem for showing or theater network ...

Страница 164: ...thout adding prefix or suffix of 0x or h Use as the separator of value Example If you want to send 0xFA 0xF1 0x01 or 0x0D type FA F1 01 0D or fa f1 01 0d End Of Line is effective only when TEXT is chosen as Command Type In this box linefeed code can be selected at the end of control command The choice is from NONE CR 0x0D LF 0x0A CR LF 0x0D 0x0A t A maximum of 255 characters can be entered in the ...

Страница 165: ...cue can be edited or deleted To confirm the cue settings click the check box on the left side of the intended cue and tap Send It is possible to issue the control command To issue it tap Status tab Auditorium Automation In the Automation screen tap a button of the intended network automation cue SPL setting 1 Login to GUI with admin or showmgr account The SPL screen is displayed ...

Страница 166: ...content 4 Set the network automation cue to SPL Tap New and set the automation cue for 4D control within the duration of Black t For details on the cue setting procedure refer to the Operating Instructions Network automation cue is effective for both scheduled showing and manual showing as well as GPO cue 4D content ...

Страница 167: ...n The Automation screen is displayed 3 Tap a button of the intended network automation cue The required control command is issued Show stopping in the mid of SPL If show stops in the mid of SPL automation cue set after the show stop point will not be executed When 4D system is to be controlled by network automation cue some 4D systems may require stopping com mand Send the command in the following...

Страница 168: ...e intermission settings refer to the Operating Instructions Show starting from the mid of 48P 50P 60P content Show stopping temporarily in the mid of 48P 50P 60P content and resuming it after that The LTC output may slip lose frame synchronization temporarily with the content over 30P frame rate when the show is resumed from the middle or after pausing This is caused because the LTC is output with...

Страница 169: ......

Страница 170: ...R515P SY SRX R515 XCT S10 LKRA 007 SRX R515 SY LKRA 009 WW LKRA 010 SY LKRA 011 WW LKRA PCAB1 SY LKRL Z511 SY LKRL Z514 SY LKRL Z519 SY LKRM U330 SY LKRM U331 SY LKRM U450 SY J E 9 878 642 01 Printed in Japan 2015 5 32 2015 ...

Отзывы: