24
Chapter 2 Installation
7
When “[ENTER] to activate”
appears, press the [ENTER] button.
The date and time and the country
are now set. The display returns to
“Date & Time”.
8
Press the [CANCEL] button twice to return to the status display.
Setting the SCSI ID
Use the SCSI Menu of the control panel to set the SCSI IDs and SCSI parity of
the AIT library and AIT drives.
About SCSI ID
For each SCSI bus, a unique SCSI ID must be set for the AIT library and AIT
drives. The default factory settings of SCSI IDs are as follows:
• Library:
0
• AIT Drive 1 (R):
1
• AIT Drive 2 (L):
2
About SCSI parity
When the SCSI parity function is enabled, parity checks are performed on all
data passing through the SCSI bus. The factory default settings for SCSI parity
are as follows:
• Library:
Enabled (YES)
• AIT Drive 1 (R):
Enabled (YES)
• AIT Drive 2 (L):
Enabled (YES)
Caution
Do not duplicate SCSI IDs on the same SCSI bus.
Notes
• If an AIT drive is not added, the Drive 2 (L) does not need to be set.
• The SCSI IDs can also be set through a browser.
1
At the status display, press the [MENU] button for 0.5 second.
Date Ja/01/2001
Time 10:10:10
Time Zone
Japan
(GMT+ 9:00)
[ENTER] to activate
Date & Time
12:34
SCSI Drive 1 (R)
Library
SCSI Drive 2 (L)
SCSI BUS
Expander
SCSI BUS
Expander
Library
Controller
AIT
Drive 1 (R)
AIT Drive 2 (L)