TVP-21
63
3. Power Supply System
Troubleshooting Flowchart Step Descriptions
Reference Flowchart B, Figure 3-3
When troubleshooting a “Unit will not turn ON” problem in previous
models the Red Power/Standby LED on the front panel, when illuminated,
would indicate that at least the Standby 5V power was functioning.
Unfortunately, there is no red standby LED on either of the two 2005
SXRD models (KDS-R50XBR1 and KDS-R60XBR1). Therefore, the only
way to visually check if the Standby 5V circuit is functioning is to press
the ON/OFF power button and watching for the Green Power/Standby
LED on the front panel to begin flashing.
Does GREEN
LED Begin
Flashing?
Yes
The first decision diamond in Flowchart B asks the question –
does the
Green (Power/Standby) LED begin flashing
? If the answer is yes then
you know that the Standby 5V and the TV Microprocessor are functioning
(the TV Microprocessor controls the Green LED).
What is the
State of the
Green LED ?
The next step is to check if the
Green (Power/Standby) LED Glows
Steady Green, Continuously Flashes, or if the Red Protection LED
begins flashing
.
If the
Green (Power/Standby) LED glows steady
then the Power-On
sequence was successfully completed, and the power supply system and
microprocessor communications are working fine. If there is still no video
displayed or audio heard then your troubleshooting efforts should be turn
to solving a video, audio, or lamp section defect.
If the
Green (Power/Standby) LED flashes continuously
then there is a
communications problem between the microprocessors. In most cases, it
will be a communications problem between the TV microprocessor on the
DSU-Board and the ATI microprocessor in the Q-Box module. Confirm
that all cables and connectors between the DSU-Board and the Q-Box
module are securely seated and undamaged. If all connections are good
then the most likely defect suspect is the Q-Box module. The fact that
the unit successfully completes the power-on sequence indicates that the
TV microprocessor is functioning properly.
If the
Red (Power/Standby) LED begins flashing
then the DE
microprocessor has detected a system failure and has placed the unit in
protection mode. The Red (Power/Standby) LED flash sequence (number
of flashes between pauses) should be noted an proceed the indicated
Protection Mode troubleshooting flowchart(s).
Does GREEN
LED Begin
Flashing?
No
Let us go back one-step in the flowchart and follow the path for the
situation when the Green (Power/Standby) LED does not begin flashing
after the unit receives an ON command.
The first step in troubleshooting a no Green (Power/Standby) LED
symptom is to confirm that the TV is securely plugged into a active AC
outlet.
No
Is AC 110 V
Present
at CN 6014 ?
Содержание KDS-R60XBR1 - 60" Rear Projection TV
Страница 1: ...Models KDS R50XBR1 KDS R60XBR1 Diagnostics and Troubleshooting Course TVP 21 Training Manual ...
Страница 49: ...TVP 21 46 Disassembly Procedures Wire Routing Diagrams Wire Routing Diagrams ...
Страница 50: ...TVP 21 47 Disassembly Procedures Wire Routing Diagrams cont ...
Страница 51: ...TVP 21 48 Disassembly Procedures Wire Routing Diagrams cont ...
Страница 52: ...TVP 21 49 Disassembly Procedures Wire Routing Diagrams cont ...
Страница 53: ...TVP 21 50 Disassembly Procedures Wire Routing Diagrams cont ...
Страница 58: ...TVP 21 55 Chapter 2 Initial Contact Analysis ...
Страница 72: ...TVP 21 69 4 Protection Circuits Troubleshooting Flowcharts Flowchart C 1 Figure 4 2 ...
Страница 73: ...TVP 21 70 4 Protection Circuits Flowchart C 2 Figure 4 3 ...
Страница 74: ...TVP 21 71 4 Protection Circuits Flowchart C 3 Figure 4 4 ...
Страница 75: ...TVP 21 72 4 Protection Circuits Flowchart C 4 Figure 4 5 ...
Страница 87: ...TVP 21 84 5 Video Processing System No Video Flowchart D Figure 5 2 Troubleshooting Flowcharts ...
Страница 88: ...TVP 21 85 5 Video Processing System Video Distortion Flowchart E Figure 5 3 ...
Страница 89: ...TVP 21 86 5 Video Processing System Optical Block Flowchart F Figure 5 4 ...
Страница 98: ...TVP 21 95 6 Audio Processing System Troubleshooting Flowchart ...
Страница 102: ...TVP 21 99 Appendix 2005 SXRD Service Mode Options ...