2-17
SNC-RZ30N/RZ30P (E)
8. AWB & LV Standard Data Input
m
Before adjustment, make sure that confirm the following
items.
1.
Perform “Color Reproduction Adjustment” before this
adjustment
2.
Check that the data of page: 6 and address: 02 is 00.
(Completed Flag)
3.
Digital Zoom: OFF, Camera stabilizer: OFF, ICR:
OFF
Subject
Clear chart
(Shoot in color bar standard picture
frame)
Adjustment Page
F
Adjustment Address
3C to 41
Adjusting method
1) Select page: 0, address: 01 and set data: 01.
2) Shoot the clear chart in the color bar standard picture
frame.
3) Select page: 6, address: 16 and set data: 02.
4) Wait until AWB data is stabilized by passed over 2
seconds after setting it.
5) Select page: 6, address: 01 and set data: 11, and select
page: 6, address: 01 and set data: 0D in order.
6) Consequently, page: 6, address: 02 and data: 01 is
indicated on the screen, data input is completed.
Processing after Completing Adjustments
1) Select page: 6, address: 01 and set data: 00, and press
the PAUSE button of the adjusting remote
commander.
2) Select page: 6, address: 16 and set data: 00, and press
the PAUSE button of the adjusting remote commander
3) Select page: 0, address: 01 and set data: 00,
m
.
The adjustment data will be automatically input to page:
F, addresses: 3C to 41.
.
AWB & LV standard data input is possible during turn
on the power at only once.
9. AWB (Auto White Balance) Adjustment
Adjust to the proper auto white balance output data.
If it incorrectly adjusted, auto white balance and color
reproducibility will be poor.
m
Before adjustment, make sure that confirm the following
items.
1.
Perform “AWB & LV Standard Data Input” before
this adjustment.
2.
Digital Zoom: OFF, Camera stabilizer: OFF, ICR:
OFF
Subject
Clear chart
(Shoot in color bar standard picture
frame)
Filter
Filter C14 for color temperature
correction
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
42, 43, B8 to BB
Specified Value
R ratio: 2C80
±
40 h
B ratio: 5E80
±
60 h
Adjusting method
1) Place the C14 filter for color temperature correction on
the lens.
2) Select page: F, addresses: B8 to BB and set the
correlation data (shown below) for using of C14 filter.
Then, the data before input must be memorized.
Select page: F, address: B8 and set the upper bite data
that objective value of R ratio.
Select page: F, address: B9 and set the lower bite data
that objective value of R ratio.
Select page: F, address: BA and set the upper bite data
that objective value of B ratio.
Select page: F, address: BB and set the lower bite data
that objective value of B ratio.
3) Select page: 6, address: 01 and set data: A7, and select
page: 6, address: 01 and set data: A5 in order.
4) Consequently, page: 6, address: 02 and data: 01 is
indicated on the screen, data input is completed.
5) Select page: 6, address: 01 and set data: 3F.
6) Select page: 0, address: 03 and set data: 04, then R
ratio data makes display on the screen at page: 1.
7) Check that R ratio data is within specified value.
8) Select page: 0, address: 03 and set data: 05, then B
ratio data makes display on the screen at page: 1.
9) Check that B ratio data is within specified value.
10) Set the memorized original data as described in item 2)
to page: F and addresses: B8 to BB.
Содержание IPELA SNC-RZ30N
Страница 1: ...NETWORK CAMERA SNC RZ30N SNC RZ30P SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 68: ......
Страница 90: ...6 6 SNC RZ30N RZ30P E Chassis Block 2 301 302 303 303 303 304 305 ...
Страница 102: ......
Страница 104: ......
Страница 118: ......
Страница 126: ......
Страница 128: ...Printed in Japan Sony Corporation 2002 12 22 B P Company 2002 SNC RZ30N UC SNC RZ30P CE E 9 955 377 01 ...