2-5
SNC-RZ30N/RZ30P (E)
2-1-4. Adjusting Remote Commander
The adjusting remote commander is used for changing the
calculation coefficient in signal processing, EVR data, etc.
The adjusting remote commander performs bi-directional
communication with the unit. The resultant data of this bi-
directional communication is written in the non-volatile
memory.
1. Using the adjusting remote commander
1) Connect the adjusting remote commander to the
LANC terminal (IF-088 board CN703) with Relay
Tool for Adjustment Commander.
n
The Relay Tool will have pin
1
coincide with pin
1
of the CN703.
2) Adjust the HOLD switch of the adjusting remote
commander to “HOLD” (SERVICE position).
If it has been properly connected, the LCD on the adjusting
remote commander will display as shown in Figure.
3) Operate the adjusting remote commander as follows.
.
Changing the page
The page increases when the EDIT SEARCH
+
button is pressed, and decreases when the EDIT
SEARCH
_
button is pressed. There are altogether
16 pages, from 0 to F.
Hexadecimal
0 1 2 3 4 5 6 7 8 9 A B C D E F
notation
LCD Display
0 1 2 3 4 5 6 7 8 9 A b c d E F
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Page
Data
Address
.
Changing the address
The address increases when the FF (
)
) button
is pressed, and decreases when the REW (
0
)
button is pressed. There are altogether 256
addresses, from 00 to FF.
.
Changing the data (Data setting)
The data increases when the PLAY (
”
) button is
pressed, and decreases when the STOP (
p
) button
is pressed.
There are altogether 256 data, from 00 to FF.
.
Writing the adjustment data
The PAUSE button must be pressed to write the
adjustment data (D, E, F, B, C page) in the non-
volatile memory.
(The new adjustment data will not be recorded in
the non-volatile memory if this step is not performed.)
4) Select page: 0, address: 01, and set the data to 01, and
enables Page D, E, F, B and C to be adjusted.
5) After completing all adjustments, set data: 00 to page:
0, address: 01 and turn off the main power supply
once.
2. Precautions upon using the adjusting remote
commander
Mishandling of the adjusting remote commander may erase
the correct adjustment data at times. To prevent this, it is
recommended that all adjustment data be noted down
before beginning adjustments and new adjustment data
after each adjustment.
Содержание IPELA SNC-RZ30N
Страница 1: ...NETWORK CAMERA SNC RZ30N SNC RZ30P SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 68: ......
Страница 90: ...6 6 SNC RZ30N RZ30P E Chassis Block 2 301 302 303 303 303 304 305 ...
Страница 102: ......
Страница 104: ......
Страница 118: ......
Страница 126: ......
Страница 128: ...Printed in Japan Sony Corporation 2002 12 22 B P Company 2002 SNC RZ30N UC SNC RZ30P CE E 9 955 377 01 ...