2-30
SNC-RZ30N/RZ30P (E)
Supply the power from
an AC adaptor
SNC-RZ30N/RZ30P
I/O PORT tool
Alarm board
D-sub 9 pins
(for RS-485)
TV monitor
PC that is installed the
SNC-RZ30 Modify Tool
Adjuster software
Memory Stick with
+
PC card adapter
(MSAC-PC2)
D-sub 9 pins
(for RS-232C)
Connection
1.
Remove the bottom plate (base plate assembly) of the
SNC-RZ30N/RZ30P. (Refer to Section 1-4-5.)
2.
Turn on the power of PC.
3.
Connect each equipment according to the following
figure.
4.
Set the DIP switch S001 to 1110 of the SY-303 board.
5.
Attach the Memory Stick, that is written in updating
program, with PC card adaptor to PC card slot A drive
(LED side).
6.
Connect the AC adaptor to DC IN connector on the
SNC-RZ30N/30P, turn on the power of the SNC-
RZ30N/RZ30P. (Confirm the Power LED blinking
(Debug mode))
7.
Confirm the clock on PC is set correctly at date and
time. If incorrectly, set them to correctly.
8.
Install the SNC-RZ30 Modify Tool to PC.
9.
Start the SNC-RZ30 Modify Tool. Then, SNC-RZ30
Modify Tool is displayed.
10. Click Connect button. Then the following dialog box
is displayed.
2-7. Setting for Hyper Terminal
Performs the initial start setting as to hyper terminal.
1.
Start the hyper terminal of Windows.
2.
Type a new connection name (example; “SNC-RZ30”)
in the box, select icon.
3.
Click OK button.
4.
Select port that is connected between PC and SNC-
RZ30N/RZ30P from the “Connection Method (N)”.
n
Normally, there is no problem by selecting at
“COM1”. However, there is differing in case of PC
configurations.
5.
Communication state is set as follows.
Communication speed 9600bps
Data bit
8
Varity
Noting
Stop bit
1
Flow control
Noting
Setting is completed as above-mentioned.
n
To start this communication state at next time, save this
setting state. That is, click “File” tag on the File menu,
clicks “Save” and type the File name on the File name box.
Then, save this setting state.
2-8. Update of Software
For update of software, there are two methods as follows.
.
Debug mode: Using the PC card and serial
communications
.
Normal mode: Using the PC card and CGI mode
2-8-1. Debug mode
Equipment required
.
I/O PORT tool (J-6432-900-A)
I/O PORT tool consists of a harness I/O PORT (J-6432-
910-A) and an alarm board (J-6432-920-A).
.
SNC-RZ30 Modify Tool software (J-6432-850-A)
.
Personal computer (Hereafter referred to as PC)
.
AC adaptor (1-468-626-31)
.
UTP category 5 cross cable (for confirmation)
Содержание IPELA SNC-RZ30N
Страница 1: ...NETWORK CAMERA SNC RZ30N SNC RZ30P SERVICE MANUAL 1st Edition ...
Страница 10: ......
Страница 68: ......
Страница 90: ...6 6 SNC RZ30N RZ30P E Chassis Block 2 301 302 303 303 303 304 305 ...
Страница 102: ......
Страница 104: ......
Страница 118: ......
Страница 126: ......
Страница 128: ...Printed in Japan Sony Corporation 2002 12 22 B P Company 2002 SNC RZ30N UC SNC RZ30P CE E 9 955 377 01 ...