3-11
SNC-RZ30N/RZ30P (E)
No
Yes
Is the flexible flat cable (MP1)
correctly connected?
Check the signal around
the connector, then
replace MP1 or the
MDR-19 board.
Operation failure of pan
Connect the flexible flat cable
(MP1) correctly.
No
Yes
Is the harness (SEN1)
correctly connected?
Check the signal around the connector,
then replace the SE-656 board,
MDR-19 board or SEN1.
Connect the harness
(SEN1) correctly.
During pan operation (up and down
movement), the unit hits the mechanical
end point of each upper side and down
side forcefully. After this, the pan does
not operate normally.
3-7-1. Operation failure of pan