2-6(E)
FDDR-7000 IM
2-3. Installation of Optional Boards
1
2
SCS-15
DPR-88 (Slot No.8 and 9 only)
DPR-88
PSW3
x
6
D washers
(
*
1)
DPR bracket
PSW3
x
6
PSW3
x
8
<Type 3>
This Type’s Optional Boards
Slot No.
Optional board
Pre-installed board
8, 9
DPR-88 board
SCS-15 board
(BKFD-7110)
(BKFD-7500)
10
DPR-88 board
SCS-15 board
(BKFD-7110)
1.
Remove the DPR bracket and the screws (PSW3
x
6)
from the pre-installed board.
2.
After checking the installation direction of the optional
board, connect the optional board to the connectors on
the pre-installed board.
n
When installing the optional board, make sure that the
connectors are connected tightly. If the connectors
cannot be connected completely, the optional board
may be placed in the other way.
3.
Install the optional board by the DPR bracket and the
screws (PSW3
x
6).
n
When installing the one DPR-88 board in the SCS-15
board, be sure to put the two D washers, as shown in
the right figure.
n
Each optional boards must be installed in the
corresponding order. Install each optional boards by
referring to the following table.
If the optional board is installed in an incorrect order, the
system is not activated properly.
.
SCS-15 board :
Install the SCS-15 board in the order of the slot
number 9 and 8.
.
DPR-88 board :
Install the DPR-88 board in the order of “
2
of the
slot number 10”, “
1
and
2
of the slot number 9”
and “
1
and
2
of the slot number 8”. (Refer to the
figure on the right.)
(
*
1) : When installing the DPR-88 board marked with
2
in the SCS-15
board, the D washers are not use.