1-12(E)
FDDR-7000 IM
1-5. Installation and Removal of Exterior Parts
Rack angle
B4
x
5
PWH3
x
8
B4
x
5
B4
x
5
B4
x
5
B4
x
5
Side plate (right)
Side plate (left)
B4
x
5
B4
x
5
B4
x
5
B4
x
5
B4
x
5
Power unit
Handles
Rack angle
PSW4
x
8
B4
x
5
3. Side Plate (Right)
(1) Turn off the power switch.
(2) Remove the front panel. (Refer to “1. Front Panel” in
this section.)
(3) Remove the eight screws (B4
x
5) and the rack angle.
(4) Remove the sixteen screws (PWH3
x
8, B4
x
5) and
the side plate (right).
(5) Install the side plate (right) in the reverse order of the
steps (1) through (4).
4. Side Plate (Left)
w
Allow for more than five minutes interval after turning the
power off, remove the power unit.
To avoid shock hazards, never remove the power unit just
after turning the power off.
(1) Turn off the power switch.
(2) Remove the front panel. (Refer to “1. Front Panel” in
this section.)
(3) Remove the eight screws (B4
x
5) and the rack angle.
(4) Remove the four screws (PSW4
x
8) securing the
power unit.
(5) Hold the handles and pull out the power unit from the unit.
(6) Remove the sixteen screws and the side plate (left).
(7) Install the side plate (left) in the reverse order of the
steps (1) through (6).