Chapter 4
Menu Settings
4-21
Chapter 4 Menu Settings
Resetting time data
Press the
[F2]
(TIMER RESET) button.
The internal time code generator is reset according to
the setting of the
[F1]
(TIMER SEL) button.
Resetting CTL data
The time data display becomes 00H00M00S00F and
all edit points are erased.
Resetting TC or UBIT data
The internal time code generator is reset and the time
data display becomes 00H00M00S00F (TC) or 00 00
00 00 (UBIT). Edit points are not affected.
Notes
• Time data read by the time code reader cannot be
reset.
• Time data cannot be reset when the internal time code
generator is locked to external time codes or time
codes read by the time code reader.
Setting the user bit value
1
Press the ALT button, then select off by pressing
the
[F2]
(ID PRESET) button.
2
Press the ALT button again, then select UBIT by
pressing the
[F1]
(TIMER SEL) button.
3
Enter the desired user bit value in hexadecimal
notation using the numeric buttons.
(Press the 0 to 5 buttons while holding down the
SFT button to enter the letters A to F.)
4
Press the
[F3]
(TIMER SET) button.
Recording the current time
1
Select df by pressing the
[F9]
(DF/NDF) button
(DVW-A500/1 and 500/1 only).
2
Select free by pressing the
[F8]
(RUN MODE)
button.
3
Enter the target time with the numeric buttons
while verifying the data in the data entry window.
4
When the target time arrives, press the
[F3]
(TIMER SET) button.
The time code generator starts operating from the
specified time.
4-3-2 Setting the Time Code
Reader (TC SEL)
Press the
[F5]
(TC SEL) button to select the time code
to be read by the time code reader during playback.
VITC: Reads VITC.
AUTO: Reads VITC when the playback speed is +/
–1/2 times normal speed or less, and LTC when it
is greater than +/–1/2 times normal speed.
LTC: Reads LTC.
Depending on the time code recorded on a tape, VITC
or LTC appears on the display.
Time codes that are read by the time code reader or
played back are output from the TIME CODE OUT
connector.
4-3-3 Setting the Time Code
Generator (TCG SOURCE/MODE)
There are two ways to record time codes on the VTR.
One way is to record the output of the VTR’s internal
time code generator. The other is to directly record
time codes that are input from an external time code
generator.
The output from the internal time code generator can
either be set to a specified initial value, or
synchronized with an external time code generator.
Selecting the time code generator
Press the
[F6]
(TCG SOURCE) button repeatedly to
select the time code generator.
int: Selects the time code generated by the internal
time code generator.
ext: Selects an external time code input to the TIME
CODE IN connector, or synchronizes the internal
time code generator to an external time code
generator.
Содержание DVW-500/1
Страница 18: ...1 1 Features Chapter 1 Overview 1 6 Chapter 1 Overview ...
Страница 86: ...4 7 SET UP Menu 4 44 Chapter 4 Menu Settings Chapter 4 Menu Settings ...
Страница 100: ...5 14 Chapter 5 Recording Playback 5 4 Playback Chapter 5 Recording Playback ...
Страница 120: ...6 2 Advanced Automatic Editing 6 20 Chapter 6 Editing Chapter 6 Editing ...