Menu List
A-10
Appendix
Appendix
The values enclosed in a box one factory settings.
Items Related to Operation Panels (100s)
Function
Item
Settable range
101
[0]
1
MAXIMUM TAPE
SPEED
SELECTION
FOR SEARCH
DIAL ENABLE
102
(DVW-A500/1)
[0]
1
2
Item number
[ 35]
×
35 (shuttle
×
24)
×
24
Selects the maximum analog Betacam tape speed in
search mode.
Note
The maximum digital Betacam tape speed in search mode
is 50 times normal tape speed no matter what this setting is.
0: 35 times normal tape speed in shuttle mode using the
search dial and during fast forward and rewind.
1: 35 times normal tape speed during fast forward and
rewind. 24 times normal tape speed in shuttle mode
using the search dial.
2: 24 times normal tape speed in shuttle mode using the
search dial and during fast forward and rewind.
Determines how the unit is set to search mode.
0: The unit enters search mode when you rotate the search
dial in all modes except recording and edit modes.
1: The unit enters search mode when you press the
SHUTTLE, JOG or VAR button.
[dial direct]
via search key
MAXIMUM TAPE
SPEED
102
(DVW-A500P/1)
[0]
1
2
[ 42]
×
42 (shuttle
×
24)
×
24
Selects the maximum analog Betacam tape speed in
search mode.
Note
The maximum digital Betacam tape speed in search mode
is 50 times normal tape speed no matter what this setting is.
0: 42 times normal tape speed in shuttle mode using the
search dial and during fast forward and rewind.
1: 42 times normal tape speed is the maximum tape speed
during fast forward and rewind. 24 times normal tape
speed in shuttle mode using the search dial.
2: 24 times normal tape speed in shuttle mode using the
search dial and during fast forward and rewind.
AUDIO SELECTED
LINE OUT
103
(DVW-A500/1
and A500P/1)
[0]
1
2
[manual]
auto AFM/LNG
select
auto LNG select
Selects the audio signal output to the MONITOR OUTPUT
connectors.
0: The audio signal selected by the AUDIO INPUT/
MONITOR SELECT buttons on the upper control panel
or the
[F9]
(MON-L SEL) or
[F10]
(MON-R SEL) button in
the PF2 menu factory setting) is output to the MONITOR
OUTPUT connectors.
1: The AFM audio (CH-3 and CH-4) is selected during
metal tape playback. The LNG audio (CH-1 and CH-2) is
selected during oxide tape playback. Signal output is in
stereo.
2: The audio signal selected by the AUDIO INPUT
MONITOR SELECT buttons on the upper control panel
or the
[F9]
(MON-L SEL) or
[F10]
(MON-R SEL) button in
the PF2 menu (factory setting) is output to the MONITOR
OUTPUT connectors. When the AFM audio is selected,
the LNG audio is output to the MONITOR OUTPUT
connector automatically when the variable speed
playback mode is activated.
×
×
Содержание DVW-500/1
Страница 18: ...1 1 Features Chapter 1 Overview 1 6 Chapter 1 Overview ...
Страница 86: ...4 7 SET UP Menu 4 44 Chapter 4 Menu Settings Chapter 4 Menu Settings ...
Страница 100: ...5 14 Chapter 5 Recording Playback 5 4 Playback Chapter 5 Recording Playback ...
Страница 120: ...6 2 Advanced Automatic Editing 6 20 Chapter 6 Editing Chapter 6 Editing ...