Appendix
A-23
Appendix
Item number
Settable range
Item
Function
610
[0]
1
2
3
REGEN CONTROL
MODE
Specifies whether the time code signal is automatically
regenerated or not, during editing using the control panel of
the VTR.
0: When the VTR is used as a recorder for editing, the time
code generator automatically regenerates the time code
signal using the time code on the tape during assemble
or insert edit no matter what the setting of the
[F6]
(TCG
SOURCE) button in the TC menu is.
1: When the VTR is used as a recorder for ediing, the time
code generator automatically regenerates the time code
signal using time code of the time code generator on the
tape during assemble edit only, no matter what the
setting of the
[F6]
(TCG SOURCE) button in the TC
menu is.
2: The time code generator operates in accordance with the
setting of the
[F6]
(TCG SOURCE) button in the TC
menu, regardless of the operating mode of the VTR.
3: The time code generator regenerates the time code
signal in the off-tape LTC signal when edit preset is set
to ON (assemble/insert), regardless of local or remote
control.
auto (assem & insert) edit
auto assemble edit
manual
assemble & insert
Содержание DVW-500/1