OPERATING MANUAL PAT-800/805 version 1.09
36
- The bandwidth of test current results from the measuring system with adjusted touch current which
simulates human perception and reaction, in accordance with EN 60990: 2002.
4.10 Measurement of current, power consumption and voltage
Press
VA
. After that meter is prepared for
measurement.
Press
START
.
The measurement may be stopped before
the set time runs out by pressing
STOP/ESC
.
After measuring is completed, read the
result.
Symbols
and
are blinking.
During the measurement
current I is displayed
alternatively with the time
of measurement.
Press
ENTER
, if this test is successful (
is displayed)
or
STOP/ESC
, when the test result is negative (
is
displayed).
Notes:
During the measurement in the test socket the voltage of mains is present.