Alarm / Failure / Recommendation List – Columbus
Control
Anomalies
Sond – Probe’s anomaly during the control in Check Up.
Ignition Block – The message appears if the system has been is turned off
during Ignition (after Preload) by an external device: the system will stop only
when it goes in Run Mode.
Link Error – Lack of communication between the LCD or K control panels and
the control board.
Cleaning On – Periodic cleaning in progress.
Flashing Hours - Wrong time and date in the event of prolonged power failure.
T
HE ANOMALIES DO NOT ORIGINATE THE SHUTDOWN OF THE EQUIPMENT
.
To switch off the device, in case of emergency, you must do the normal shutdown of
the equipment. To do this, press the off button for 3 seconds and allow it to deactivate
until the word off appears on the display.
All alarms cause the machine to switch off with information about the error and
activation of the alarm led. It will be necessary to reset the alarm and restart. To reset
the machine, press the "On/Off" button for 3 to 4 seconds until you hear a beep
accompanied by the message "Reset alarms in progress".
If the resetting of alarms is successful, new information is displayed - Reset alarms
Successful. In the Off state, if for any reason the smoke temperature rises above 85ºC,
the unit enters deactivation mode.
Содержание K100
Страница 149: ...144 ...
Страница 150: ...145 ...
Страница 151: ...146 ...
Страница 165: ...160 26 Flow chart 26 1 Flow chart K100 K200 K500 and K600 Lighting ...
Страница 166: ...161 ...
Страница 167: ...162 Disabling ...
Страница 168: ...163 26 2 Flow chart K300 and K400 ...
Страница 169: ...164 ...
Страница 170: ...165 Disabling ...