h) Screw the accessory on the ventilator using 2 screws
A
(DIN 7981 5,5x13).
Figure 115 – Fitting the air guide to the free-standing fire unit
i) Screw the air outlet duct in the ductable air guide using 4 screws
B
(DIN 7981
4,2x9,5).
Figure 116 – Securing the air outlet duct to the free-standing fire unit
15.1.
Electrical connections
j) The unit is equipped with a cable attached that allows you to connect the ventilator to the
electronic control unit. You need to connect the terminals of the connection cable in the kit
to the terminals in that cable
.
Important note: The connections must respect the colour system.
(The attached cable is located near the base of the unit