IMPORTANT INVERTER
SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING!
The inverter cover must be opened only after shutting off the inverter ON/OFF switch located at the
bottom of the inverter. This disables the DC voltage inside the inverter. Wait five minutes before
opening the cover. Otherwise, there is a risk of electric shock from energy stored in the capacitors.
WARNING
Before operating the inverter, ensure that the inverter AC power cable and wall outlet are grounded
properly.
WARNING
Opening the inverter and repairing or testing under power must be performed only by qualified service
personnel familiar with this inverter.
WARNING!
Do not touch the PV panels or any rail system connected when the inverter switch is ON, unless
grounded.
WARNING!
Under single fault conditions, the Safe DC voltage is only guaranteed when using modules of up
to 95Voc.
CAUTION!
This unit must be operated under the specified operating specifications, as described in the latest
technical specification datasheet provided with the unit .
NOTE
The StorEdge Connection Unit is NEMA type 3R rated . Unused glands should be sealed with
appropriate seals.
CAUTION!
HEAVY OBJECT. To avoid muscle strain or back injury, use proper lifting techniques, and if required - a
lifting aid when removing or replacing.
NOTE
Use PV modules rated according to IEC 61730 class A..
NOTE
The symbol
appears at grounding points on the SolarEdge equipment. This symbol is also used in
this manual.
SolarEdge
StorEdge
-Single
Battery/High
Capacity
Installation
MAN-01-00283-
1.1
6
IMPORTANT INVERTER SAFETY INSTRUCTIONS