
Energy Meter Status
Displays the total energy produced during the last day, month, year and since inverter installation.
D a y [ W h ] :
0 . 0
M o n t h [ K W h ] :
0 . 0
Y e a r [ K W h ] :
0 . 0
T o t a l [ K W h ] :
0 . 0
If a meter is connected to the inverter, the following status screen, showing the power and energy
readings, is displayed instead of the above screen.
If the meter is set to Import, there are two status screens, with the first line displaying: "Export
Meter" or "Import Meter". The following is an example of an export meter status:
E x p o r t M e t e r
S t a t u s :
< O K / E r r o r # >
P o w e r [ W ] :
x x x x x . x
E n e r g y [ W h ] :
X X X X X . X
l
Status
: Displays OK if the meter is communicating with the communication board.
l
<Error message>
: If there is a meter error, it is displayed in this line. Refer to
l
Power (W)
: Depending on the meter type connected to the inverter, this line displays the exported
or imported power in Watts.
l
Energy (Wh)
: The total energy read by the meter, in Watt/hour. The value displayed in this line
depends on the meter type connected to the inverter and its location:
o
If a bidirectional meter is connected at the consumption point, this value is the consumed energy.
o
If the meter is installed at the production connection point, this value is the energy produced by
the site.
o
If the meter is installed at the grid connection point, this value is the energy exported to the grid.
If the inverter is connected to the SolarEdge server, this value will also be displayed in the monitoring
portal.
NOTE
This data is accumulated according to an internal real-time clock.
Telemetry Status
This screen displays the last power optimizer telemetry received. The display changes as each power
optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for some time in order
to observe the power optimizers' report process.
M o d u l e : 1 0 2 8 8 0 6 3 1 B
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] : 4 0 . 0
V d c _ I [ V ] : 3 8 . 3
I _ i n [ A ] : 7 . 8
T e m p [ C ] : 2 8 . 0
l
Module
: Power optimizer serial number
l
Energy
: power optimizer energy
Chapter 7: User Interface
SolarEdge
-
StorEdge
-Single
Battery/High
Capacity
Installation
MAN-01-00283-
1.1
53