30
ELECTRONICAL CONTROLLER
Setting the Tramline Bout
1-
PRESS and RELEASE the
button to toggle between
the tramline sequence and tramline bout number display.
The 3rd and 4th digits flash indicating the tramline bout
number currently set.
2-
PRESS and RELEASE the
button to cycle the tramli-
ne bout trom 1 to 15.
Fig. 75
8.6 FAN RPM / FAN ALARMS – C4
To display the fan’s speed in rpm
Select channel 4 using the central button
.
Fan alarms
The fan’s minimum turning speed can be programmed.
Under 2 Km/h these alarms will deactivate.
Fan’s minimum speed
1-
Select channel 4.
2-
Press and hold
button for more than 5 seconds.
3-
Hold it and press
to change value and digits as exp-
lained in former cases. Default speed is 3800 rpm.
4-
Release all buttons to resume the normal position
Selecting the fan’s number of impulses per revolution (de-
fault value is set to 2).
PLEASE NOTE
: FAN’S NUMBER OF IMPULSES PER REVOLU-
TION SHOULD ALWAYS BE 2. ONLY USE THIS PROGRAMMING
MODE IN CASE OF MALFUNCTION.
1-
TO SELECT PROGRAMMING MODE 2, DO THE FOLLOWING:
WHILE SWITCHING ON THE ELECTRONICAL CONTROLLER
USING REAR SWITCH, PRESS
IN MACHINE MODELS
NEUMASEM OR
PIN MODEL NEUMASEM PLUS.
2-
PRESS
IN MODEL NEUMASEM OR
IN NEU-
MASEM PLUS TO CHANGE THE CHANNEL AND SELECT
CHANNEL 4 (FAN).
3-
PRESS AND HOLD
TO MODIFY THE FLICKERING
DIGIT (IT SHOULD ALWAYS BE 2).
4-
RELEASE THE BUTTON TO CHANGE BACK TO NORMAL
POSITION.
8.7 SEED SHAFT RPM – C5
Select channel 5 using the central button
.
40 seconds after the seed shaft stops turning, an alarm
beeps 5 times consecutively. If it remains still, this alarm will
repeat every 30 seconds.
To turn off the beeping, switch off the screen and switch it
on again. This alarm will deactivate under 2 Km/h.
The seed shaft’s alarm can be deactivated by pressing the
button
for more than 5 seconds on the selected
channel. The screen will display “Off”. In this situation the
alarm will not be activated even if the screen is switched off
and on again.
8.8 HOPPER LOW LEVEL ALARM – C6
When the seed level is below the sensor, an alarm is activa-
ted and beeps 5 times consecutively. In this case the screen
will display «
ALA
».
Activate and deactivate hopper level alarm
1-
Select channel 6 using
.
2-
Press and hold
button and...
3-
Press the central button to select «
0
» (alarm is
off) or «
1
» (alarm is on).
4-
Release the buttons to change back to the nor-
mal position.