important Safety instructions
i
mportant
S
afety
i
nStructionS
SavE ThESE INSTRUCTIONS
This manual contains important safety instructions. Read all safety, installation and operating instructions before
operating the Uninterruptible Power System (UPS). Adhere to all warnings on the unit and in this manual. Follow
all operating and user instructions. Individuals without previous training can install and operate this equipment.
It is not intended for use with life support and other designated critical devices. Maximum load must not exceed
that shown on the UPS rating label. If uncertain, consult your local distributor or Sola/Hevi-Duty representative.
This UPS is designed for use on a properly grounded (earthed), 100/200, 110/220, 115/230, 120/208, 120/240 or
127/220 VAC, 50 Hz or 60 Hz supply. The factory default setting is 120/208 VAC, 60 Hz. Installation instructions
and warning notices are located in this manual.
This UpS is only for use with a four-wire input (L1, L2, N, G).
This UpS MaY NOT be used with a three-wire, single-phase utility source (L1, N, G).
ELECTROMaGNETIC COMpaTIBILITY
—The S4K6U10000 Series complies with the limits for a CLASS A
DIGITAL DEVICE, PURSUANT TO Part 15 of FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and (2) this device must accept any interference received,
including interference that may cause undesired operation. Operating this device in a residential area is likely to
cause harmful interference that users must correct at their own expense.
Operate the UPS in an indoor environment only in an ambient temperature range of 32°F to +104°F (0°C to
+40°C). Install it in a clean environment, free from conductive contaminants, moisture, flammable liquids, gases
and corrosive substances.
This UPS contains no user serviceable parts except the internal battery pack. The Off/Bypass push button does
not electrically isolate internal parts. Under no circumstances attempt to gain access internally other than to
replace the batteries due to risk of electric shock or burn. Do not continue to use the UPS if the front panel
indications are not in accordance with these operating instructions or if the UPS performance alters in use. Refer
all faults to your local distributor, Sola/Hevi-Duty representative or the Sola/Hevi-Duty Technical Support Group.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the
required precautions. Keep unauthorized personnel away from the batteries. PROPER DISPOSAL OF
BATTERIES IS REQUIRED. REFER TO YOUR LOCAL LAWS AND REGULATIONS FOR BATTERY
DISPOSAL REQUIREMENTS.
Never block or insert any object into the ventilation holes or other openings of the UPS.
DO NOT CONNECT equipment that could overload the UPS or demand half-wave rectification from the UPS, for
example: electric drills, vacuum cleaners, laser printers, hair dryers or any other appliance using
half-wave rectification.
Storing magnetic media on top of the UPS may result in data loss or corruption.
Turn the UPS off and isolate the UPS before cleaning; use only a soft cloth, never liquid or aerosol cleaners. Keep
the front and rear vents free of dust accumulation that could restrict airflow.
WaRNING
Opening or removing the cover may expose you to lethal voltages within this unit even when it is
apparently not operating and the input wiring is disconnected from the electrical source. Observe all
cautions and warnings in this manual. Failure to do so may result in serious injury or death. Refer all
UPS and battery service to qualified service personnel. Do not attempt to service this product yourself.
Never work alone.
1
Содержание S4K6U10000
Страница 1: ...S S4K6U10000 power availability On Line UPS 120 208V 120 240V USER MANUAL...
Страница 2: ......
Страница 46: ......
Страница 47: ......