112
Operation of the totalizing functions
Use the function change key to call up the totalizing functions level
Plus F6
By pressing the F6 Plus key, the weight on the weighbridge is transferred to the totalizing memory. The
transaction counter and the consecutive number are increased by 1.
Before totalizing again, the scale must be unloaded at least up to the unload factor defined in the setting
mode.
A weight value with 0 or summation without unload is displayed with "Error 55 Apply weight" (with unload
factor = 0 only a weight change is necessary).
Gross, tare and net weights are added together.
cancellation F5
Individual items can be cancelled or weighed back with the F5 Cancel key.
After pressing the cancel key, you are prompted either to load the weight to be cancelled or to enter the
consecutive number of the weight to be cancelled.
You can obtain information on the consecutive number in advance by using the key combination and F5
Plus.
Using the numeric keypad, enter the consecutive number of the item to be cancelled and confirm with F6
Accept.
If no consecutive number is entered, the weight value is taken from the scale when key F6 is pressed. If the
scale is not loaded, error message Error 46 is displayed.
Cancellation or backweighing is indicated in the print document by the designation cancellation.
The consecutive number is incremented by one and the item counter is decremented by one.
If the item counter is at 0, no further cancellation is possible, indicated by error message Error 48.
Total F4 or with the CL key
Press the F4 Total key to complete the totalizing operation.
The display now shows the gross, tare and net total, as well as the transaction counter and consecutive
number of the last operation.
Selection options for displaying the total
Clearing the totalizing memory
The following functions can be assigned to the Total function key in Setting mode:
>
Display, print and delete totalsAfter
pressing the Total function key, the totals are displayed for 3 seconds, the contents of the memory
are printed and deleted at the same time. You can then start a new totalizing procedure.
>
Display of totals only
After pressing the function key Total, the user can decide whether to clear the totalizing memory.
Press the F2 key Delete total to delete the total memory, followed by the confirmation prompt Delete
total? Pressing the keys F1 to F3 YES to delete the totalizing memory, while pressing the keys F34 to
F6 NO does not delete the totalizing memory.
If you want to continue totalizing without deleting the memory, press the key F6 Back.
Содержание 3035
Страница 1: ...www soehnle professional com Manual Terminal 3035 ...
Страница 2: ...2 ...
Страница 122: ...122 ...