77
1
Weighing and taring
Display information field
Select
which data should be displayed in the information field
>
Factory setting: Switch between the individual functions used, e.g. switching
functions inputs and outputs and organization data memory.
>
IO control: Continuous display of output and input states
>
Organizational data + database: Continuous display of the organizational data
memories.
>
Fixed tare values: Continuous display of the activated fixed tare value
memory.
>
Barcode content: Continuous display of the scanned barcode.
>
Code128 Weight value: Display Barcode128 with the current stability weight
value.
> Volume: Display volume only after activating the volume measurement
function
Factory setting: Factory setting
6
.6 Totalizing and picking
Totalize
means that the individual items are weighed one after the other, the weight is added in the total memory and
the scale is unloaded after each individual weighing.
Picking
means that the weighed positions remain on the scale. The weight is added in the total memory and the
scale returns to zero without unloading.
Changing measuring points during the picking process is not permitted.
The selection Totalize or Pick
is made in the setting mode Program settings. The selection applies to all connected weighbridges. The
following only refers to totalizing as an example.
Totalizing memory for several connected scales
A central totalizing memory is maintained for all connected scales.
Total memory capacity
A maximum of 999 bookings can be made in the totalizing memory. Afterwards, the totalizing memory must
be cleared.
6.6.1 Function keys
The function keys F1 to F6 are available to control the functions. These are assigned in 3 levels, the change
through the levels is made by the function change key.
1. Totaling functions level:
Total
Cancel
Manual
Add
F 1
F 2
F 3
F 4
F 5
F 6