86
2
Totalizing and picking
Auto totalisation/commiss.
Selection
from or on
On means that only the first position must be stored by pressing the Plus key, all
other positions are automatically stored in the totalizing memory according to
weight and stability.
Factory setting: off
running time No. Reset
Selection
under which condition the consecutive number of the totalisation /
picking is to be reset
> not active
> Clear total memory
> Switch off
> function key (activates a separate function key)
Factory setting: not active
Sum key function
Selection of
which functions are to be linked to the summary key
Displaying totals onlyAfter
pressing the Total function key, the total is displayed. The user can then decide
whether to clear the totalizing memory.
Press the F2 key Clear total to clear the total memory.
Then confirm the security prompt with the F1 to F3 keys with YES, and the total is
printed.
Display/Print/Clear total After
pressing the Total function key, the totals are displayed for 3 seconds
, the memory contents are printed and simultaneously cleared. Afterwards,
a new totalizing procedure
can
be started.
Factory setting: Display/Print/Clear
Relief factor
Input
in d via numeric keypad
The number of digit steps by which the scale must be unloaded during totalizing to
allow further weight storage in the totalizing memory. If the weight is not unloaded
the weight value is not stored in the totalizing memory, error message "Error 55
Place weight on scale".
Between 0 and 30 digit steps can be specified. At 0, you can totalise, provided that
the standstill was once gone.
Factory setting: 15 digit steps
Display information field
Select
which data should be displayed in the information field
>
Factory setting: Change between the individual functions used, e.g. totalizing
memory, organization data memory, switching functions.
>
Total: Continuous display of the totalizing memory.
>
Last item: Continuous display of the last item.
>
IO control: Continuous display of output and input states
>
Organizational data + database: Continuous display of the organizational data
memories.
>
Fixed tare values: Continuous display of the activated fixed tare value
memory.
>
Barcode content: Continuous display of the scanned barcode.
>
Code128 Weight value: Display Barcode128 with the current stability weight
value.
> Volume: Display volume only after activating the volume measurement
function
Factory setting: Factory setting
Factory setting
Execute
selection
resets all settings to factory defaults