
117
4
Check
Summation out of tolerance
Selection
inside or outside
Here it is defined whether summations into the totalizing memory may only be
made for values within the tolerance or also for values outside the tolerance.
Factory setting: Outside
Totalizing or picking
Select
Totalize or Pick for the following settings.
Totalizing
means that the individual positions are taken from the scale after being
transferred to the totalizing memory.
Picking
means that the individual items remain on the scale after being transferred
to the totalizing memory and the next items are placed on the scale.
Factory setting: summation
Auto totalizing / picking
Select
from or on.
On means that only the first position must be stored by pressing the Plus key, all
other positions are automatically stored in the totalizing memory according to
weight and stability.
Factory setting: off
running time No. Reset
Selection
under which condition the consecutive number of the totalisation /
picking is to be reset
>
not active
>
Clear total memory
>
Switch off
>
Function key (activates a separate function key)
Factory setting: not active
Sum key function
Selection of
which functions are to be linked to the summary key
Displaying totals onlyAfter
pressing the Total function key, the total is displayed. The user can then decide
whether to clear the totalizing memory.
Press the F2 key Clear total to clear the total memory.
Then confirm the security prompt with the F1 to F3 keys with YES, and the total is
printed.
Display/Print/Clear total After
pressing the Total function key, the totals are displayed for 3 seconds
, the memory contents are printed and simultaneously cleared. Afterwards,
a new totalizing procedure
can
be started.
Factory setting: Display/Print/Clear
Relief factor
Input
in d via numeric keypad
The number of digit steps by which the scale must be unloaded during totalizing to
allow further weight storage in the totalizing memory. If the weight is not unloaded
the weight value is not stored in the totalizing memory, error message "Error 55
Place weight on scale".
Between 0 and 30 digit steps can be specified. At 0, you can totalise, provided that
the standstill was once gone.
Factory setting: 15 digit steps
Содержание 3035
Страница 1: ...www soehnle professional com Manual Terminal 3035 ...
Страница 2: ...2 ...
Страница 122: ...122 ...
Страница 123: ...123 ...