Lit. No. 89451, Rev. 05
83
May 15, 2022
under "Hydraulic System" in the Getting to
Know Your Snowplow section of this manual.)
5. Completely drain the reservoir and replace the
drain plug/cap.
6. Fill the reservoir with SnowEx
®
RAPID
ACTION hydraulic fluid rated to –40°F (–40°C),
or other fluid conforming to Military
Specification MIL-H-5606 A, such as Mobil
Aero HFA or Shell AeroShell
®
Fluid 4.
SPEEDWING™, POWER PLOW™, or
Straight Blades:
Fill reservoir to within
2" to 3" (5 to 8 cm) of the top of the fill pipe.
HDV™ Blades:
Fill reservoir so that the fluid
is 1" to 1‑1/2" (2.5 to 3.8 cm) below the top of
the fill pipe.
Replace the fill plug.
MAINTENANCE
7. Remove air by turning the control ON and fully
angling the blade to the left and right several
times. Turn the control OFF.
8.
Add fluid to fill the reservoir to the proper level
as specified in Step 6. Replace the fill plug.
NOTE: Loosen fill plug slowly to relieve any
pressure in the reservoir.
9. Turn the control ON and raise and lower the
snowplow several times. Turn the control OFF.
10.
Add fluid to fill the reservoir to the proper level
as specified in Step 6. Replace the fill plug.
AeroShell
®
is a registered trademark (
®
) of Shell Oil Company.
WARNING
To prevent accidental movement of
the blade, always turn the control OFF
whenever the snowplow is not in use. The
power indicator light will turn OFF.
Содержание 6800LT
Страница 3: ......