![Smiths Kelvin Hughes Nucleus 3 5000 Series Скачать руководство пользователя страница 125](http://html.mh-extra.com/html/smiths/kelvin-hughes-nucleus-3-5000-series/kelvin-hughes-nucleus-3-5000-series_system-handbook_1305982125.webp)
KH 2020
Chap 4a
Amdt. 5
4a.9/10
July 03
AUDIO LINE IS NOT PART OF THE CABLE KIT
2m OF ABOVE CABLES SUPPLIED WITH FITTING KIT, OPTIONAL 5,10 & 15m LENGTHS AVAILABLE
(KH PART No: NNR-A332-5 (5m), A332-10 (10m), A332-15 (15m) ,A332-20(20m)
#
*
#
3 CORE (CABLE L)
SCART CABLE
AUDIO LINE 2 CORE (CABLE A)
*
*
L
N
E
L
N
E
NUCLEUS 3 6000 (SPLIT)
DISPLAY
NUCLEUS 3 6000 (SPLIT)
PROCESSOR
NNR-A59 - ARPA
NNR-A60 - ATA
NNR-A61 - EPA
REAR PANEL
SUPPLY IN/OUT
PROCESSOR CASE
SCART
SOCKET
SCART
SOCKET
POWER
SOCKET
AUDIO
SOCKET
AUDIO
SOCKET
OUTPUT
TERMINALS
TO INSTALL THE NUCLEUS 6000A
SPLIT DISPLAY
1.
2.
1.
2.
3.
4.
5.
A) DISPLAY UNIT
B) PROCESSOR UNIT
NOTE:
Refer to the dimensioned drawing opposite for hole
locations. There is the option to either have Cable
Connections to the rear of the unit or underneath
(if underneath, cut out the hole as shown, swap the
Connecting Plate and Blanking Plate over).
Fasten the Display Unit to the required location,
using the fixings and anti-vibration mounts supplied.
A 2m Cable Kit is supplied as standard with optional
5, 10, 15 & 20m kits also available.
Mark out the position of the Processor Unit, leaving
sufficient clearance for ventilation, cable access and
servicing; drill the bolt positions as shown in the
diagram.
Secure the Processor Unit in position.
Feed the ship's cables through the base of the unit and
make the connections as detailed on the appropriate
Connections Diagram(s).
Ensure that the Processor Unit is directly earthed to
the ship's earth, using the bolt provided.
See Monitor to Processor Connections Diagram
OPERATING TEMPERATURE RANGE
VIBRATION LEVELS
POWER CONSUMPTION:
380VA
COMPASS SAFE DISTANCES
PROCESSOR UNIT:
13kg
DESK CONSOLE:
65kg
AT RELATIVE HUMIDITY 0%: -15 C TO +55 C
AT RELATIVE HUMIDITY 95%: +40 C
1 TO 12.5Hz WITH AN EXCURSION± 1.6mm
12.5 TO 25Hz WITH AN EXCURSION± 0.8mm
25 TO 50Hz WITH AN EXCURSION± 0.1mm
TO A CONSTANT MAXIMUM ACCELERATION OF 10m/s
DISPLAY
2.0m
2.0m
0.8m
0.8m
GRADE 1
1/4
GRADE 2
1
PROCESSOR
CD-4556
WEIGHTS
Processor Weight : 13kg
At Relative Humidity 0% : -15°C to +55°C
At Relative Humidity 95% : +40°C
OPERATING TEMPERATURE RANGE
5
3
0
5
7
0
280
418
230
CABLE ACCESS
62.5
12mm DIA
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE STATED
Display Weight : 65kg
LOWER SIDE PANELS CAN BE
REMOVED TO ALLOW ACCESS
TO FIXING HOLES
AIR VENT
BOTH SIDES
AIR VENT LOUVRES
(10mm)
FRONT PANEL
OVERHANG
FRONT VIEW
REAR VIEW
FOR UNDERSIDE CABLE
ENTRY SWAP POSITION
OF UNDERSIDE BLANKING
PLATE AND REAR
CONNECTOR PLATE
O
56
475
64
80
215
204.5
112.5
O
56
4
5
5
.5
820 MAX.
6
0
8
682
163
6
8
2
6
2
6
2
8
475
300
150
115
REF
R
E
F
53
285
380
1
1
3
4
0
0
SIDE VIEW
UNDERSIDE VIEW
12mm DIA (IN 6 POSITIONS)
SHOWN THUS
M10 THREADED AV MOUNT
(IN 4 POSITIONS)
390
612
612
M10 THREADED BUSHES (IN 6 POSITIONS)
SHOWN THUS
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE STATED
Figure 4a - Nucleus 6000 Split Display: Installation Diagram
Содержание Kelvin Hughes Nucleus 3 5000 Series
Страница 27: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 ii Amdt 1 KH 2020 Index Introduction ...
Страница 73: ...THIS PAGE IS INTENTIONALLY BLANK KH 2020 Chap 2a July 03 2a 6 Amdt 5 ...
Страница 101: ...THIS PAGE IS INTENTIONALLY BLANK May 01 3 6 Original KH 2020 Chap 3 ...
Страница 109: ...THIS PAGE INTENTIONALLY BLANK July 03 viii Amdt 5 KH 2020 Index Chap 1 3 ...
Страница 119: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 x Amdt 1 KH 2020 Contents Chap 4 5 ...
Страница 150: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4b 12 Original KH 2020 Chap 4b ...
Страница 157: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 6 Original KH 2020 Chap 4c ...
Страница 163: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 14 Original KH 2020 Chap 4c ...
Страница 176: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 28 Original KH 2020 Chap 4c ...
Страница 234: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 6 Original KH 2020 Chap 4f ...
Страница 257: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 30 Original KH 2020 Chap 4f ...
Страница 275: ...THIS PAGE IS INTENTIONALLY BLANK July 03 5 18 Amdt 5 KH 2020 Chap 5 ...
Страница 279: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 iv Amdt 1 KH 2020 Index Chap 4 5 ...
Страница 309: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 xiv Amdt 1 KH 2020 Contents Chap 7 8 ...
Страница 355: ...May 01 7c 18 Original KH 2020 Chap 7c CD 2412 Figure 15c Control PCB Links Switches Potentiometers and Test Points ...
Страница 356: ...Original 7c 19 May 01 KH 2020 Chap 7c CD 2413 Figure 16c Modulator PCB Switches Test Points ...
Страница 357: ...May 01 7c 20 Original KH 2020 Chap 7c CD 2414 Figure 17c Rx Monitor PCB Links Switches Potentiometers Test Points ...
Страница 359: ...THIS PAGE IS INTENTIONALLY BLANK May 01 7c 22 Original KH 2020 Chap 7c ...
Страница 381: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 7d 26 Amdt 1 KH 2020 Chap 7d ...
Страница 425: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8a 22 Original KH 2020 Chap 8a ...
Страница 445: ...THIS PAGE INTENTIONALLY BLANK July 03 8aA 16 Amdt 5 KH 2020 Chap 8a Annex A ...
Страница 463: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 12 Original KH 2020 Chap 8c ...
Страница 472: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 22 Original KH 2020 Chap 8c ...
Страница 476: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8d 4 Original KH 2020 Chap 8d ...
Страница 498: ...THIS PAGE IS INTENTIONALLY BLANK Original 8e 19 May 01 KH 2020 Chap 8e ...