15
Step 10:
OPTION 3: This is only for stations with the
solenoid valve mounted off the vacuum
pump and no delay timer on the solenoid
valve.
To install the new delay timer
(Item 14)
to
the back of the control panel, find a spot
on the backpan to mount the delay timer
(see Photo 38)
.
Punch a mark on the panel through the
mounting hole on the timer.
(see Photo
39)
Drill a hole with a #20 drill bit at the
punch mark.
Screw the self tapping screw
(Item 15)
into the new hole to secure the delay timer
(Item 14)
to the panel
(see Photo 40)
The delay timer
(Item 14)
will be installed
inline directly before the solenoid valve.
Run a wire from one of the terminals
on the delay timer
(Item 14)
with one of
the female disconnects
(Item 16)
(see
Photo 41)
to the terminal block where
the red solenoid valve wire is connected.
(see Photo 43 next page)
Remove the
existing red wire for the solenoid valve
from the terminal strip. Crimp the female
disconnect
(Item 16)
onto the wire to
secure it
(see Photo 42)
.
Photo 40
15
14
Photo 39
Photo 38
14
Photo 42
16
14
16
Photo 41