WD1050
12/04/2010
Pag. 12
5.5. NON
PRESSURIZED
DEMINERALIZED
WATER
CONNECTION
The connection to a non-pressurized demineralized water supply (e.g. gravity tank) is
possible only by installing the special demineralized water pump, called "PAD5".
The PAD, optional booster pump, ensures the correct inlet water supply pressure
within the pre-set filling time.
This accessory can be fitted on any machine and must be mounted on the back of the
machine.
If the PAD pump is used, the water supply pressure must be less
than 1 bar.
We advise having the pump installed by a specialized technician, who should follow
the instructions provided.
The manufacturer will accept no responsibility for any possible damage caused
by an incorrect installation performed by an unauthorized technician.
WARNING
Make sure that the demineralized water pressure is less than or
equal to 1bar. The manufacturer declines every responsibility for
higher pressures.