fig. 51 – GW4190 series: the detergent intake hose connections are accessible in the side cabinet. P3 is always optional.
INSTALLATION ON STAND
If the device is installed on a stand (e.g. for GW1160, GW4060: Smeg product
“B6040”
) with having height (base
height) "HB", all the measurements of height above the supporting surface provided in this document must be
increased by the said height “HB”.
HMi = Hi + HB
Where:
Hi
= normal height stated in the document
HB
= height of appliance stand
HMi
= height recalculated for appliance installed on stand
fig. 52 – Smeg B6040 Stand.