User Manual
GW2145 - GW1160 - GW4060 - GW4190
Page 61 - 86
ALARM ID
DESCRIPTION
USER ACTION
AF:37
Drainage problems when using a
mixture of water.
The use of a mixture of water is an option adopted in special
cases to cool the water discharged into the drain.
Check:
1. The intake water temperature; if the water is not cold enough
(recommended T<25°C) there may be difficult in achieving the
target temperature.
2. Problems with drain; check that the hoses and drain
connections meet the specified requirements.
A-:41
P1 detergent intake anomaly
1. Check that the detergent intake nozzle is correctly positioned
in the can.
2. Check for detergent leaks (pools of detergent around the
device).
This code provides a
warning;
it is not an alarm which cuts out
the appliance. Operation of the device can be continued by
pressing the
Start/Stop
button.
A-:42
P2 detergent intake anomaly
Proceed as for AF:41
A-:43
P3 detergent intake anomaly
Proceed as for AF:41
AF:54
Door opening detected with cycle
in progress. Door interlock
microswitch malfunction.
1. Make sure the door is closed properly before starting a cycle.
2. Do not force the door open with a cycle in progress; always
use the buttons provided on the appliance to stop a cycle and
open the door.
3. Check there is nothing between the door and the appliance’s
chamber preventing the door from closing properly.
3. Follow the
DEFAULT PROCEDURE
described above. If the
alarm does not disappear, follow the
RESET PROCEDURE.
AF:56
Door locking device malfunction,
automatic opening failure
Always make sure the door is closed properly before starting a
cycle.
Try to open the appliance again by pressing the
Door opening
button.
If necessary, release the door lock by hand as described in this
manual.
Follow the
DEFAULT PROCEDURE
described above. If the alarm
does not disappear, follow the
RESET PROCEDURE.
AF:58
Dryer heating failure. (Only on
GW4060, GW4190).
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.
AF:67
Dryer motor “cooling”
malfunction. Cooling is included at
the end of the drying phase to
bring the load processed and the
heating elements to a safe
temperature. (Only on GW4060,
GW4190).
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.