2.
Silicone hose for connection between intake pipe and peristaltic pump.
3.
Detergent intake filter, fitted directly on the suction nozzle pipe.
WARNING
It is essential that the label on the intake pipe corresponds to the type of detergent being used.
Refer to the following colour code:
1. White/clear: P1, alkaline detergent
2. Red: P2 acid neutralising agent
3. Blue: P3, additive
Incorrect connections (e.g. if detergents P1 and P2 are exchanged) will reduce effectiveness of the
process.
Connection errors leading to the mixing of different chemicals in the intake systems may cause
irreparable damage to parts of the circuit.
Detergent intake system connection errors lead to the loss of Warranty cover for the parts
concerned (peristaltic pumps, detergent suction and intake circuit, and level and flow sensors if
installed).
The intake pipe is supplied complete with intake filter. The filter pushes into place on the pipe.
Make sure that the filter is always fitted and correctly positioned to keep the detergent
dispensing system in good working order.
Check regularly that the silicone hose is properly fixed to the stainless steel intake pipe and that
there are no leaks. Use suitable fittings (e.g. plastic ties) to secure the silicone hose to the
stainless steel pipe.
fig. 38 – Detergent intake
STANDARD version
. Fitting the detergent intake pipe to the can. Fit the rubber cap over the
top of the can for a perfect, secure connection. The pipe is supplied complete with intake filter.