User Manual
GW2145 - GW1160 - GW4060 - GW4190
Page 19 - 86
BUTTONS
DESCRIPTION
600
With appliance in standby
A0 value associated to the selected cycle, if the cycle includes a
thermal disinfection phase.
With cycle running
Display function which starts from the thermal disinfection
phase: displays the A0 value reached.
The value reached during the thermal disinfection phase is
displayed during the phases which follow.
[The parameter is displayed on two consecutive display screens
from firmware version 1.11.0.33. The value in thousands is
indicated by the suffix "t", in units with the suffix "u"]
-
F5
With appliance in standby
Number of phases in the program
With cycle running
Current phase
N.B.: Washing cycles always start with a short draining phase to
bring the device to the standard starting condition: this phase is
called “phase 0”.
-
PR 03
If the user does not give any commands for 5 seconds, the
display shows the program selected.
Door opening
The door is opened automatically by means of an electric lock; opening is only permitted
in conditions of safety for the user.
The user simply presses the button; there is no need to hold it down.
The button also provides an “
Escape”
function; it is pressed to quit the procedure for
displaying or modifying an appliance parameter. In this case, it has to be held down (2
seconds).
-
Selection
Program selection buttons. The letter “P” and the name of the selected program appear
on the display.
These buttons can be used to
increase or decrease
the current value during
modification
of an appliance parameter.
4.2.1
A0 PARAMETER DISPLAY
The parameter is displayed on two consecutive display screens from firmware version 1.11.0.33.
The A0 parameter can reach high values (eg typical A0 = 12000) and will appear on two consecutive screens;
thousands display screen (t-Thousands) and units screen (u-units), the value in thousands is indicated by the suffix "t"
units with the suffix" u ". The transition from one screen to the next occurs automatically after 3 seconds or by short
press of the "
Functions
" key.
fig. 8 – The A0 value is displayed split into thousands (t) and units (u)