User Manual
GW2145 - GW1160 - GW4060 - GW4190
Page 33 - 86
4.11
PROGRAM SPECIAL OPTIONS
1. Temporary disabling of demi water
2. Delayed start
(function introduced from firmware version 4.6.xx.yy).
The “Special Options” menu is accessed by pressing the “Start/Stop” and “Door Opening” buttons simultaneously.
To scroll through the special functions: press the “Functions” button and release at once.
The special options only apply for 1 single cycle, executed after selection of the option. After execution of the cycle,
the default values are restored.
Special options must be confirmed by pressing the “Start/Stop” button; after confirmation, the program display
returns to the screen.
If the option is not confirmed, after 10 seconds without any action the system quits the option and the last parameter
set is maintained.
N.B.: the current date and time must be set to allow the “delayed start” setting to function
correctly.
4.11.1
DELAYED START - Setting the hours
Delayed start: initially, the display shows “dh:00”.
The selection keys can be pressed to set up to a max of 12 hours (“dh:12”).
The “clock” LED remains on while the selection is made and the value set flashes until confirmed.
fig. 19 – Delayed start setting screen
4.11.2
DELAYED START - Starting the program and display
To start a program with delayed start set: Hold down the “Start/Stop” (as when starting the cycle normally).
The display shows, in alternation (switching every 2 seconds):
the time remaining before the start
of the program (format “hh:mm”) / the
program selected
(“Pr:XX”).
The “clock” LED remains steady when the time remaining is displayed.
At the end of the delay time: the program starts and from this point onward the contents of the display are the same
as for a normal cycle.
fig. 20 – Once the cycle start command is given, the display alternates the program selected with the time remaining before it actually starts.