HRX-MM-L012
Chapter 4 Service Procedure
HRGC Series
4.3 Replacement procedure
4-43
Mounting
1.
Mount the 3-way proportional valve assembly. (Fixing screw x 6)
2.
Connect the hoses (3pcs) and tighten the hose bands.
[Key point]
Hose band 4.5Nm
3.
Mount the connector [EV1] (option), put wires into the locking wire saddle, and close the
saddle.
4.
Connect the wires of the temperature sensor.
[Key point]
For the connection of the wires of the temperature sensor, refer to “4.3.1
Replacement of temperature sensor”.
Check the hose is not twisted after connecting.