HRX-MM-L012
Chapter 4 Service Procedure
HRGC Series
4.3 Replacement procedure
4-21
Mounting
1.
Connect the spiral tube (2pcs).
2.
Apply Loctite to the fan fixing bolt and fix the fan to the motor with it. (Fan fixing bolt x 1)
[Key point]
The fan fixing bolt gets in the slit of the shaft.
3.
Mount the fan motor to the bracket. (Motor mounting screw x 4)
4.
Mount the start-up capacitor. (Screw x 1)
5.
Mount the bracket. (Fixing bolt x 4)
6.
Mount the connector [FAN1] of the fan motor.
7.
Put wires into the locking wire saddles (4pcs).
8.
Connect the ground wire. (Screw x 1)
9.
Fix wires with the tie wrap (2pcs).
10.
Put the wires of the solenoid valve (yellow) into the locking wire saddle
s
(2pcs) and
close the saddle.
11.
Fix the charge port with the tie wrap (1pcs).
Check
When the fan motor is replaced, rotate the fan by hand and check that it turns with no
interference.