HRX-MM-L012
Chapter 4 Service Procedure
4.3 Replacement procedure
HRGC Series
4-26
<HRGC005-
∗
>
Table 4-13 Part number of service parts (level switch)
Part number
HRG-S0173
Removal
1.
Open the locking adjuster clamp and disconnect wires.
2.
Remove the connectors of the level switch [LS1] (2pcs).
3.
Remove the nut with a spanner/wrench.
4.
Remove the lid of the tank and take out the level switch from the tank.
Fig. 4-11 Removal of level switch
Level switch
3.
Nut
Front side
Front
side
1.
Remove the
connectors
[LS1].
Seal
Lid
2.
Locking adjuster clamp