6.5.4
Chunk Data Control
To access chunk data control in CameraSuiteClient, the property visibility must be set to Expert or Guru.
Controls are located at bottom of the Device Properties window. Figure 72 shows chunk data control.
Figure 72: Chunk Data Control
•
ChunkModeActive:
enable or disable chunk data ( if chunk data is disabled then normal image is
sent )
•
ChunkSelector:
select chunk that will become active
•
ChunkEnable:
enable or disable active chunk ( mandatory chunks cannot be disabled )
When chunk mode is enabled and acquisition is started, enabled chunks will be displayed in new tab that
appeared under Image Processing Properties. Figure 73 shows chunk data values tab.
Figure 73: Chunk Data Values
95