Installing the Motion Sensor
The motion sensor is most suitable for guarding the bedrooms. Use the motion sensor to
monitor the passage leading to the bedrooms or hallway.
You needed to power up the sensor first. Undo the
screw on the back of the motion sensor and remove
the cover of the battery compartment. Connect a
9V alkaline battery to the connector wire.
If you are going to install the motion sensor outdoor,
please change the sensitivity to low by changing the
sensitivity jumper from HI to LOW. You also needed
to change that zone to an Alert Zone. (Refer to p.
XX)
Then close the battery cover and re-insert the screw.
Mount the ball-head joint on the wall with screws provided. Slide the
back of the sensor into the ball-head joint. The mounting angle can be
adjusted.
Keep sensors within 30m (100 ft) of Control Panel.
Walk in the detected area. If the motion is detected, a read light inside the sensor will glow. If
the red light does not glow, motion has not been detected and you should re-position the sensor.
Repeated this procedure until your motion is detected. There should be no movement in the
detected area during the 20 seconds.
Note:
When installing the motion sensor, avoid placing it near heat or cold producing devices
(i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement, especially caused by
changes in temperature may trigger the Motion Sensor and cause false alarms. Please
carefully test your Motion Sensor so that it will only be triggered by people.
Battery notes for the System
When you are reminded by the system that any sensors are in low battery, please change the
battery accordingly. The sensors, keychain remotes and accessories are generally designed to
have a battery life of around
one year
. Since there are large variations in different working
environment, we suggest replace new batteries every
nine months.
The alkaline batteries in the main unit are expected to use as back up purpose in normal
working condition. We suggest you replace the alkaline batteries every
nine months
after you
have installed new batteries or right after a shortage of electricity in your premises.