DOL 434 LPV
44
Technical Manual
1.
Check the pages.
Compare the pages in the display with your notes or the pictures taken before the update. If you have lost
the setup, you have to set up the pages again.
2.
Check configuration after the update in the menu
Show connection
Check that the connections are as noted or as in the pictures taken before the update.
3.
Set/check that operation and climate values are the same as before the update according to the
notes entered in the form.
4.
Reset the climate components to automatic mode.
5. Check that the controller works as it should by testing all components.
This can be done in the menu
Manual/Auto
. You can test each function by activating manual mode.
6.
If the set-up has been copied from another house controller, all winch motors must be re-calibrated.
The controller will only load the calibration if it comes from the same house controller. Therefore, a calibra-
tion is required if it comes from another controller.
7.
Set the function
Use password
as required.
6.5 Control parameters
6.5.1 Control modes
6.5.1.1 Adaptive control
From the factory the controller is set to adaptive control.
SKOV recommend the use of adaptive control.
Adaptive control is used for, for example, ventilation, tunnel cooling, heating and humidity control (as an alterna-
tive to PID control).
At adaptive control the climate controller will maintain a setting by continuing to adjust the control to maintain the
required level. Furthermore, it will take into account variable parameters, such as outside temperature and
adapt the control to the changed conditions.
Therefore, at adaptive control a lot less settings must be made to adapt the control to the house in question.
Figure 7: Adaptive control will automatically adapt to the changed conditions. The stability of the control depends on the set-
tings of adaption time.
Check via the management program FarmOnline Explorer how stable the climate controller is able to keep the
control at the required level.