Technical Manual
Minimum ON time
At heating requirement: The heating relay is ON for minimum this time.
Minimum OFF time
When the heating relay is released, it is OFF for minimum this time.
At PID regulation
P band
Working range for 0-10 V heating.
Integration time
Reaction time for heating.
Longer time: slow reaction.
Shorter time: faster reaction.
See also the section
.
6.5.4 Cooling
6.5.4.1 Side cooling
When side cooling and humidification are set up on the same relay, the cycle time and ON time are shared.
Cycle time
ON + OFF time of the side cooling relay.
Minimum ON time
At cooling requirement: The side cooling relay is ON for minimum this time.
P band
The proportional band according to which cooling is controlled.
Integration time
Reaction timer of the cooling.
Short time: Immediate reaction.
Long time: Slow reaction.
6.5.5 Humidity
6.5.5.1 Humidity control
Maximum temperature
reduction
At Temperature reduction.
Setting the maximum reduction from temperature setpoint when humidity ventilation
is used.
High outside tempera-
ture and humidity
The function requires use of an outside humidity sensor.
In areas with high outside temperature and humidity, the standard humidity control
does not have a large effect as it just brings in more hot and humid air into the
house. It may therefore be an advantage to stop it and possibly let the inside tem-
perature rise.
Selecting the required humidity control based on climate conditions and the ani-
mals’ needs (
Use humidity control
.
Block humidity control. Increase temperature
+ block humidity control
).