DOL 434 LPV
20
Technical Manual
Number of light sensors
Setting the number of light sensors.
Light control settings
Light sensor settings
Selecting light sensor type.
Main light
This is used to name a light source according to function, so that it can be recog-
nized in the menus and alarms.
Light intensity unit
Lux or percentage.
Light sensor controlled
Use boost
This is used for light fixtures that cannot be switched on unless they start at maxi-
mum power for a short period of time.
Max. light intensity
Setting how wide a scale you should be able to adjust the light within. This en-
ables you to adapt the light control to the type of light source used in the house.
The scale can be set from 1-1000 lux and the factory setting is 100 lux.
Inspection light
Setting up if inspection light is available or not.
Inspection light settings
Duration:
Setting an active period and light sources for the inspection light.
Active:
Activation or deactivation of inspection light.
Light intensity:
When a light source has been installed with a light dimmer, a re-
quired light intensity (lux) for the inspection light can also be set.
Light dimmer boost time
Setting the duration of the boost when the light is turned on.
When light has been installed with a light dimmer, it can turn on using a so-called
boost. It means that it turns on with the maximum intensity and that it then adjusts
according to the setting.
Light active at failure
Setting if the light should switch on at power failure.
When installing light you must decide how the function is to re-
act in an emergency situation.
Yes:
In case of control failure, the light is on.
No:
In case of control failure, the light is off.
3.8.1.1 Light sensor
When using a light dimmer, the light can be controlled by a sen-
sor.
The light sensor is also used for alarming purposes.
Select which sensor type to use.
If
Other Sensor
is selected, it must be calibrated.
3.8.2 Water
Number of water meters
Setting the number of water meters.
Liters pr. pulse
Setting the number of liters that runs through the water meter for every pulse.