![Skope 400 A Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/skope/400-a/400-a_instruction-manual_1289238041.webp)
37
12.3 DESCRIPTION OF INPUTS
Symbol
Description
SC
Cycle probe. – temperature -50/+80 °C
SA
Ambient probe. – temperature -50/+80 °C
P
Safety pressure switch. ON/OFF / NC contact / I min 25 mA
T
Stock thermostat. ON/OFF / NC contact / I min 25 mA
I
Flooding. Electrode conductivity.
EL
Free input ON/OFF / I min 25 mA
12.4 DIP SWITCH
Symbol
Description
1
Setting of the time alarms (long pre-heating, long and short pre-cooling).
2
Pressure switch re-setting.
3
Automatic start due to power cut.
12.5 BUTTONS
ON-OFF
Power on: lights up the screen and starts at point 0.
Power off: It turns off the machine at any time. It turns off the display light
and leaves the time showing. All relays off.
UP/DOWN: Move between menu options. Increase or decrease programmer
values.
OK: Confirm menu options or programmer values.
MENU: To enter the main menu. To exit one level when navigating the menus.