35
6- Empty cubes with uneven
edges and too white.
Water loss in container. The
pump loses prime.
Repair water loss.
Obstructed injectors.
Clean injectors.
The curtain slats don’t close
properly, and water is lost.
Adjust the curtain slats or clean
the axle (it may contain lime that
won’t allow the slats to turn
smoothly).
7-The machine won’t stop
even full of cubes.
Stock
thermostat
incorrectly
adjusted or defective.
Adjust to the factory setting
marked with a red point over the
thermostat label. Change it if is
defective.