32
10.2 CYCLE PROBE
Indicates the temperature of the cycle probe on the screen. If it is defective, the machine will stop and indicate
“Cycle probe”.
10.3 AIR TEMPERATURE PROBE
If, for any reason, the probe is defective, instead of indicating the temperature, it will indicate “_____”. This alarm
will not affect the operation of the machine, as this function is purely for information purposes.
10.4 HIGH PRESSURE
This alarm will appear when the pressure in the machine reaches 30 Bar. The switching may be manual or
automatic as regulated by the electronic plate.
If dip-switch 2 is in the ON position, the switching will be automatic. The minimum downtime for safety is
60 minutes and the “temporizing” alarm will appear on the display.
If dip-switch 2 is in the OFF position, the switching will be manual and “Pressure” will appear on the
display.
10.5 LONG PRE-HEATING
If the detachment time is longer than the time defined, the “long harv.time” alarm will appear on the display.
10.6 LONG PRE-COOLING
If the production time is longer than the time defined, the machine will stop working while showing the “long
freez.time” alarm on the display.
10.7 SHORT PRE-COOLING
If the production time is shorter than the minimum variable production time, the machine will start detaching. If
this continues, the error will be shown on the “short freez.time” display.
Содержание 400 A
Страница 1: ...INSTRUCTIONS MANUAL Sold separated...
Страница 10: ...6 MACHINE STACKING DIAGRAM...
Страница 12: ...8 3 7 THERMOSTAT CONNECTIONS Machine stacking kit...
Страница 30: ...26 6 4 WATER AND DRAINAGE CONNECTIONS ICE CHUTE...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ...The Company reserves the right to change models and specifications without prior notice Cod 30243 7 2017...