12
SECTION 7.1: PREPARING THE OPENING
Before installing the fire, check the flue for correct operation using a smoke pellet, all of the
smoke should be drawn up the flue and exit correctly from the terminal.
If problems are found
DO NOT
fit the fire until corrective measures have been completed.
Before running the gas supply into the opening, offer up the fire box to the fireplace to check
the fit is good.
Ensure that it slides in correctly, the sealing face sits flat and square to the wall and that the
base is level
At this stage it is essential to ensure that the flue outlet of the fire is not obstructed in any
way, and it is recommended that you check the distances available for the flue spigot (see
section 8A below)
Remove the fire box and apply the self-adhesive sealing strips around the edge of the rear of
the firebox frame, approximately 5mm in from the edge.
Mark and drill the fire frame in the relevant points on the wall place rawplugs in place.
Push the appliance back into the opening, centralise and securing in to place with the screws
provided.
Note: Fibre Rawlplugs might be preferred rather than plastic Rawlplugs as the heat
from the fire might affect their efficiency.
When fitting the appliance without the use of a chimney liner then the spigot plate
must be fitted see section 8A
Note: In no circumstance should you use soft soldered connections to or
underneath the burner tray.
Note: DO NOT install or use the appliance without this seal
in place.
Failure to fit this seal correctly will cause the flue suction
to act upon the area under the burner tray resulting in
poor performance, and overheating of this area.
You can now decide where to route your gas pipe, knock
out holes are provided in the rear and side of the fire box
for use where concealed pipe work is required.
Knock out the holes with a screwdriver and a sharp tap
from a hammer and fit the rubber grommet supplied.
Содержание Royal Solo Apex
Страница 38: ...38 SECTION 20 LIST OF SPARES Royal 600 Manual Controls C1 C 4 C2 C3 B1 ...
Страница 39: ...39 SECTION 20 LIST OF SPARES Royal 1000 Manual Controls A5 A6 A4 A7 C1 C 4 C2 C3 B1 ...
Страница 40: ...40 Royal 400 Remote Control A5 A6 A4 A7 C1 C 4 C2 C3 ...
Страница 41: ...41 Royal 600 Remote Control A2 A3 A4 A1 A2 A3 A1 A4 ...
Страница 42: ...42 Royal 1000 Remote Control 5E 2E 3E 4E 6E 13E 10E 12E 7E 11E A1 A2 A3 A4 ...
Страница 43: ...43 Royal 400 Ceramics Royal 600 Ceramics Royal 1000 Ceramics F1 F3 F5 ...