SECTION 4: VENTILATION
The 400 and 600 models do not normally require purpose provided ventilation.
The 1000 model
does
require purpose made ventilation to an outside area in accordance with
current regulations.
However, if a second appliance operating within the same room or space must be taken into
consideration when assessing ventilation.
When commissioning the appliance spillage is detected, then amongst other problems there
may be insufficient natural ventilation for correct operation of the flue.
If spillage is detected with windows closed, but the appliance does not spill with the windows
open, this demonstrates a lack of natural ventilation.
If spillage is still detected with the windows open, the flue is at fault.
Installation of an air brick is the best solution to lack of ventilation.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2.
Air Vents fitted under or within the immediate vicinity of the appliance must not be used as
adverse effects to the operation of the Flame Safety Device (FSD) may occur.
Spillage detected during commissioning is almost always a result of poor flue performance
that cannot be corrected by any amount of ventilation
.
For Republic of Ireland ventilation may be required, see IS 813, ICP3, IS
327, and any other rules in force.
Section 5: SITE REQUIREMENTS
The fireplace opening should be inspected and repairs made where necessary.
This appliance requires a natural draught flue system which may be one of the following;
225mm x 225mm (9in x 9in) brick or stone (ALL MODELS WILL FIT)
175mm (7”) Minimum diameter lined flue (ALL MODELS WILL FIT)
125mm (5”) minimum diameter lined brick or stone. (400 AND 600 MODELS ONLY)
125mm (5”) minimum diameter twin wall flue conforming to BS 715, (400 AND 600 MODELS
ONLY)
175mm (7”) minimum diameter twin wall flue conforming to BS 715, (ALL MODELS WILL FIT)
Any existing draught device situated under the fireplace must be sealed off.
The opening area must be non-combustible.
Содержание Royal Solo Apex
Страница 38: ...38 SECTION 20 LIST OF SPARES Royal 600 Manual Controls C1 C 4 C2 C3 B1 ...
Страница 39: ...39 SECTION 20 LIST OF SPARES Royal 1000 Manual Controls A5 A6 A4 A7 C1 C 4 C2 C3 B1 ...
Страница 40: ...40 Royal 400 Remote Control A5 A6 A4 A7 C1 C 4 C2 C3 ...
Страница 41: ...41 Royal 600 Remote Control A2 A3 A4 A1 A2 A3 A1 A4 ...
Страница 42: ...42 Royal 1000 Remote Control 5E 2E 3E 4E 6E 13E 10E 12E 7E 11E A1 A2 A3 A4 ...
Страница 43: ...43 Royal 400 Ceramics Royal 600 Ceramics Royal 1000 Ceramics F1 F3 F5 ...