24
SECTION 17: TROUBLESHOOTING GUIDE cont:
Fire runs for a time and then cuts
off?
Pilot flame shrinks when fire is on high
?
Fire smells when first lit or in use?
Remote control
Excessive room draught or flue pull, rectify.
Loose or faulty thermocouple, rectify.
O.D.S system in operation.
Firebox grommet seal not fitted, rectify.
Lint in pilot aeration hole, clean thoroughly internally
Poor gas flow to fire, check pressure with fire on high.
If pressure is low, remove any restriction in pipe work
or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
Air leak under base of firebox, rectify.
Lint in pilot aeration hole, clean thoroughly internally.
Firebox grommet seal missing, rectify
Newness smell from brand new appliance.
Spillage occurring, call installer to carry out spillage
test and rectify any problems.
Low temperature sealants or combustible materials
used in incorrect positions.
Air leak under base of firebox, rectify
Firebox grommet seal missing rectify.